iii

Federal Communications Commission Statement

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy, and if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at his own expense.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.

Exhibit J (Consumer Instructions)

This equipment complies part 68 of the Federal Communications Commission Rules.  On the outside
surface of this equipment is a label that contains, among other information, the FCC registration number.
This information must be provided to the telephone company.

As indicated below, the suitable jack (Universal Service Order Code connecting arrangement) for this
equipment is shown.  If applicable, the facility interface codes (FIC) and service order codes (SOC) are
shown.

A FCC-compliant telephone cord and modular plug is provided with this equipment.  This equipment is
designed to be connected to the telephone network or premises wiring using a compatible modular jack
which is Part 68 compliant.  See installation instructions for details.

If this equipment causes harm to the telephone network, the telephone company will notify you in advance
that temporary discontinuance of service may be required.  But if advance notice is not practical, the
telephone company will notify the customer as soon as possible.  Also, you will be advised of your right to
file a complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations, or procedures that
could affect the operation of the equipment.  If this happens, the telephone company will provide advance
notice in order for you to make necessary modifications in order to maintain uninterrupted service.

If trouble is experienced with this equipment (the model of which is indicated below) please contact
MultiTech Systems, Inc. at the address shown below for details of how to have repairs made.  If the
equipment is causing harm to the network, the telephone company may request you to remove the
equipment from the network until the problem is resolved.

Содержание CommPlete CC9600

Страница 1: ...CC9600 Chassis User Guide ...

Страница 2: ...thout obligation of Multi Tech Systems Inc to notify any person or organization of such revisions or changes Revision Date Description A B 3 31 97 5 27 97 Manual released Manual updated C 11 17 97 Manual revised to include new FCC information and removal of service information Multi Tech CommPlete RASExpress MultiExpress MultiExpress Fax MultiModem MultiModemZDX MultiModemManager and the Multi Tec...

Страница 3: ...Service Order Code connecting arrangement for this equipment is shown If applicable the facility interface codes FIC and service order codes SOC are shown A FCC compliant telephone cord and modular plug is provided with this equipment This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant See installation in...

Страница 4: ...2205 Woodale Drive Mounds View MN 55112 612 785 3500 Fax 612 785 9874 FCC Fax Warning The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone fax machine unless such message clearly contains in a margin at the top or bottom of each page or the first page of the transmission the date and time it ...

Страница 5: ...the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate ele...

Страница 6: ... déconnexion Les prises d alimentation doyent être installées près de l équipement et doyent être faciles d accès Afin de réduire les risques de choc toutes les ouvertures doivent être couvertes pendant le fonctionnement normal de l équipement Advertencias de Seguridad No son necesarios ajustes manuales del equipo para la conexión a la corriente de la red dentro del voltaje y frecuencia establecid...

Страница 7: ...gsledningen er beregnet til at fungere som afbryder Stikkontakten skal installeres nær ved udstyret og skal være let tilgængelig Nedsæt risikoen for stød ved at tildække alle udstyrets åbninger under normal drift Power Requirements AC 100 240 V 50 60 Hz 8 A Alimentation Requise AC 100 240V 50 60 Hz 8 A Requisitos de potencia AC 100 240V 50 60 Hz 8 A Stromaufnahme AC 100 240V 50 60 Hz 8 A Strømfors...

Страница 8: ...viii CommPlete Communications Server ...

Страница 9: ...lation Notes 6 Installation 7 Safety Warnings 7 Connections 8 Appendix Appendix A Installing 3rd Party Software 10 Installing Citrix WinFrame Software on the CommPlete 10 Installing Microsoft Windows NT Software on the CommPlete 12 Installing SCO UNIX Software on the CommPlete 13 Installing USL Novell UNIXWare Software on the CommPlete 14 Installing BSD UNIX Software on the CommPlete 15 ...

Страница 10: ...x CommPlete Communications Server ...

Страница 11: ...CommPlete Communications Server 1 1 1 Introduction ...

Страница 12: ...ator Key Features Four independent segments for any combination of T1 Starter or PRI Starter segment kits Data bus eliminates serial cables Ethernet bus reduces network cables to one T1 bus works with T1 card to eliminate the need for a channel bank Control bus delivers management reporting and control information to the controller Side venting cooling fans and a heat sensor with built in reportin...

Страница 13: ...odel Number CC9600 Number of Slots 16 Number of Fans 6 External Connectors Two AC power receptacles Environmental Temperature range 0 40 C 32 104 F Humidity range 0 95 noncondensing Dimensions 31 1 48 3 36 8 cm 12 25 19 14 5 in H W D Weight 11 kg 25 lb Limited Warranty Two years ...

Страница 14: ...CC9600 Chassis User Guide 4 CommPlete Communications Server ...

Страница 15: ...CommPlete Communications Server 5 2 Installation ...

Страница 16: ...Consult the manuals for your other components PS9600 MR9600 MTRAS96 and MTxxxxHD8 before they are installed into the CC9600 To reduce emissions be sure to use blanking plates to cover empty slots in the CC9600 chassis Only connect like circuits In other words connect SELV Secondary Extra Low Voltage circuits to SELV circuits and TN Telecommunications Network circuits to TN circuits Power Supply Po...

Страница 17: ... hazardous condition such as loading heavy equipment in the rack unevenly When connecting the equipment to the supply circuit be sure to check equipment nameplate ratings to avoid overloading ciruits which may cause damage to over current protection devices and supply wiring Be sure to maintain reliable earthing for rack mounted equipment Pay particular attention to supply connections other than d...

Страница 18: ...l power from the chassis The power supplies are connected in parallel so that both power supplies supply power to all power busses in the chassis To remove all power from the left power supply disconnect the left power cord to remove all power from the right power supply disconnect the right power cord 10BaseT Ethernet connector to external concentrator SELV 10Base T Ethernet connector to server N...

Страница 19: ...CommPlete Communications Server 9 Appendix ...

Страница 20: ...I608 driver disk to the root directory of the CommPlete s hard drive 4 Install any software that you need which requires the CD ROM drive or the floppy drive 5 Remove the IDE CD ROM from the system At the main menu select Winframe setup Under Options select Add Remove SCSI devices Highlight IDE CD ROM drive and click on Remove 6 At the Control panel select Devices Highlight the atdisk device Selec...

Страница 21: ...0 for the IRQ for the first card Enter I O address 220 and IRQ 11 for the second card Enter I O address 230 and IRQ 12 for the third card 17 Leave the port numbers at the default settings unless you have a good reason to change them 18 Start setting up your WinStations refer to the Citrix WinFrame documentation ...

Страница 22: ...k on Remove 6 At the Control panel select Devices Highlight the atdisk device Select the Startup button and click on BOOT This will put a circle in the boot section 7 Exit the menus and shutdown the CommPlete system 8 Remove the RASCard MT3334HD8 modems and remove the DA9600 card and cables 9 Re install the RASCard and MT3334HD8 modem cards 10 Restart the CommPlete system 11 Install the ISI608 dri...

Страница 23: ...SCO UNIX Software on the CommPlete This procedure steps you through the process of installing SCO UNIX software from The Santa Cruz Operation Inc on the CommPlete system This procedure can be performed only by using the optional DA96002 load card Procedure to be added at a later date ...

Страница 24: ...L Novell UNIXWare Software on the CommPlete This procedure steps you through the process of installing UNIXWare software from USL Novell on the CommPlete system This procedure can be performed only by using the optional DA96002 load card Procedure to be added at a later date ...

Страница 25: ...UNIX Software on the CommPlete This procedure steps you through the process of installing BSD UNIX software from the University of California Berkely on the CommPlete system This procedure can be performed only by using the optional DA96002 load card Procedure to be added at a later date ...

Страница 26: ...CC9600 Chassis User Guide 16 CommPlete Communications Server ...