background image

TB12SE/TB12PE TUFFTRUK POWER BUGGY• OPERATION MANUAL — REV. #0 (04/01/22) — PAGE 29

Troubleshooting (Error Codes)

The machine controller detects a wide variety of faults or errors. Diagnostic information can be obtained on the 3100R fuel gauge display where an error code in the format 
“Err ##”. The troubleshooting chart below describes the error code faults and their possible causes. Whenever a fault is encountered the first action should be to turn off the ignition 
and push in the E-stop button. Then pull out the E-stop button and turn the ignition back on to see if the fault clears. This is the RESET procedure: If the error code does not clear 
after the machine RESET, turn off the ignition switch and remove the 35-pin connector. Check the connector for correction or damage, clean it if necessary, and reinsert it. If the 
error is still seen then the wiring and connections on the machine should be checked for breakages or loose connections. The table below should be used as a reference once the 
above checks have been carried out.

Error Code

Symptom

Possible Problem

Solution

1

HW fail-safe  
Motor fault voltage (hardware failure)

Motor voltage does not correspond to 
throttle request?

Check for short in motor or motor wiring.

10

Main brake driver over current.

Short circuit or overloaded controller 
driver?

Check brake controller driver. Reference 
Curtis controller owner's manual.

15

Main current dropped.

Main contactor failed to open?

Clean the contactor switch.

17

Main contactor welded.

Main contactor fault / failed to close?

Replace contactor.

33

Supervisor DIR check fault.

Program issue?

If fault is on an external signal, check 
that signal first. If no problem with 
the external signal, likely indicates an 
internal controller fault. Reference Curtis 
controller owner's manual

34

External supply fault.

Under voltage?

Check control wiring circuit, 
potentiometer wiring in particular.

36

EM-brake driver open drain.

Hold voltage set at 90%?

Check brake electrical connectors. 
Check continuity. Replace motor brake 
if failed.

54

Pre-charge failed/fault.

Low battery voltage?

Check battery voltage. 25V (11/12V per 
battery) is good condition, 22V (9/10V 
per battery) or lower is bad battery 
condition.

Short circuit on traction motor outputs?

80

HPD sequencing 
HPD fault present > 10 seconds.

Misadjusted throttle?

Adjust. See maintenance section.

Broken throttle potentiometer or throttle 
mechanism?

Replace.

92

Traction motor open / not connected. 
Controller cannot see the motor.

Short circuit in the motor?

Check the resistance across the motor 
leads.

99

Undervoltage cutback.

Battery voltage < undervoltage 
threshold?

Check connection at battery or controller. 
Check no corrosion on the battery 
terminals.

Quick checks if no reading on the fuel gauge and the machine does not operate:

1.  Check 10-amp ignition fuse located on the backside of the control panel. Reference 'Electronic Component Locator" drawing.

2. Check 100-amp main fuse*located on the backside of the control panel. Reference 'Electronic Component Locator" drawing.

2. When changing the 100-amp fuse, ensure that the positive battery cable is fully disconnected. Electrical maintenance should be carried out 
  by a qualified person.

ERROR CODES

Содержание TuffTruk EB500

Страница 1: ...ication or associated parts manual visit our website at www multiquip com OPERATION MANUAL THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES MODEL TB12SE TB12PE EB500 WALK BEHIND POWER BUGGY 24VDC...

Страница 2: ...alk Behind Power Buggy Safety Information 3 6 Specifications Buggy 7 Specifications Electric Motor 8 Noise And Vibration 9 Dimensions 10 General Information 11 Components 12 13 Inspection 14 15 Operat...

Страница 3: ...al injury GENERAL SAFETY CAUTION NEVER operate this equipment without proper protective clothing shatterproof glasses respiratory protection hearing protection steel toed boots and other protective de...

Страница 4: ...ace over which you will travel Look for holes drop offs and obstacles Look for rough and weak spots on docks ramps or floor ALWAYS Look for oil spills wet spots and slippery surfaces Look for soft soi...

Страница 5: ...ne in proper running condition Fix damage to machine and replace any broken parts immediately The entireTuffTruk tub shroud wheels etc should be cleaned after every use Make sure there is no buildup o...

Страница 6: ...underneath wheel to prevent rolling DO NOT use the TuffTruk to transport people When transporting the TuffTruk on a truck or trailer know the overall height to avoid contacting overhead obstructions s...

Страница 7: ...ive 24 VDC Electric Motor Speed Forward Up to 4 0 mph 6 43 km h Speed Reverse Up to 1 5 mph 2 42 km h Steering Radius Outside Dia 56 in 1 422 mm Brake System Dead Man Handle Dump Control Mechanical Du...

Страница 8: ...MER Type Permanent Magnet DC Electric Motor Speed Control Method Curtis 1228 Controller Starting Method Electric Max RPM No Load 2900 Input Voltage 24 VDC Wattage 750 X 2 1500W Poles 4 Protection Clas...

Страница 9: ...obtained using the operating condition of the machine that generates the most repeatable but highest values in accordance with the applicable standards for the machine 3 Per EU Directive 2002 44 EC th...

Страница 10: ...s Table 4 Dimensions Reference Letter Dimension in mm A 34 20 869 B 16 50 419 C 70 30 1 786 D 41 90 1 064 E 39 20 995 F 10 9 277 G 7 40 188 H 28 60 726 I 53 0 1 340 J 33 40 848 K 5 50 140 L 33 40 848...

Страница 11: ...del 1229 Speed Controller ECU This controller provides functional and directional control of theTuffTruk buggy It allows the buggy to start and stop or move in a forward or reverse direction This cont...

Страница 12: ...GE 12 TB12SE TB12PETUFFTRUK POWER BUGGY OPERATION MANUAL REV 0 04 01 22 COMPONENTS 1 4 5 6 11 12 17 13 14 3 2 9 8 18 7 15 16 19 22 23 24 21 20 25 10 Figure 2 TuffTruk Walk Behind Power Buggy Component...

Страница 13: ...tor controller to release the brake Microswitch is located inside handle 11 Dump Control Lever Push the lever forward to place the tub in the dump position vertical 12 Free Wheel Brake Bypass Switch M...

Страница 14: ...the battery cables CAUTION NEVER disable or disconnect the emergency stop switch It is provided for operator safety Injury may result if it is disabled disconnected or improperly maintained CAUTION AL...

Страница 15: ...k and make sure that the power buggy s steering turns freely and that there is no binding This section is intended to assist the operator with the initial start up of the unit It is extremely importan...

Страница 16: ...he motor controller J1 3 to release the brake 2 230v 110v 50Hz 60Hz 1 EMERGENCY STOP SWITCH 2 230v 110v 50Hz 60Hz 1 IGNITION SWITCH BATTERY GAUGE LOW BATTERY LEVEL DIAGNOSTIC GAUGE Figure 7 Deadman Le...

Страница 17: ...cessary to determine the grade of the path TheTB11G E buggies can travel up or down slopes not exceeding 25 Figure 12 DO NOT travel on steeper slopes To determine the grade of your path of travel use...

Страница 18: ...uk A B TUB BUCKET DUMPING 1 To place the tub in the dump position Figure 14 pull back on the dump lever and release The tub will automatically rotate to the vertical position and dump its contents Fig...

Страница 19: ...ease the RED deadman lever and come to a complete stop Brake is now set 2 Place the ignition switch in the OFF position 3 Block wheels if on a slope or incline EMERGENCY SHUTDOWN 1 Push the EMERGENCY...

Страница 20: ...2 MAINTENANCE Table 5 Power Buggy Maintenance Schedule Check Item OPERATION DAILY Periodic Maintenance Interval Every 25 Hrs Every 50 Hrs Every 100 125 Hrs Every 200 Hrs Tub Clean X X Tub For Cracks D...

Страница 21: ...owerinthisstand bymode battery fully charged and maintains the batteries at full charge and extends battery life OFF IGNITION SWITCH EMERGENCY STOP SWITCH PUSH 3 Remove the battery charger power cable...

Страница 22: ...the FWD REV cable Figure 21D away from throttle bracket 8 Remove the two bolts Figure 21E that secure the throttle bracket to the frame 9 Loosen the nut Figure 21F that secures the potentiometer to th...

Страница 23: ...ures the output shaft of the potentiometer to the throttle arm 6 Remove support blocks and reinstall control panel Figure 22 Throttle Arm Gap 4 MM NOTICE Ensure when the forward speed lever is release...

Страница 24: ...and 2 Torque all lug nuts Figure 25 in sequence DO NOT torque the wheel lug nuts all the way down Tighten each lug nut in 3 separate passes as defined byTable 6 CAUTION DO NOT attempt to repair or mod...

Страница 25: ...he tub by yourself TUB TIPPING BRACKET MAINTENANCE 4 With two people lift the tub and tipping bracket onto the chassis Figure 29 Make sure the tipping bracket pivot bar rests within the tipping slots...

Страница 26: ...cured firmly under the tub catch Figure 31 Adjust the tub catch if necessary LOCKING LEVER Figure 31 Tub Latch TUFFTRUK BUGGY STORAGE For storage of the buggy for over 30 days the following is recomme...

Страница 27: ...onnectors should be free of corrosion Make sure battery cable post or eyelet connectors are tight to avoid arcing Charging Guidelines When the batteries have been discharged to full as indicated on th...

Страница 28: ...ervisor SW 4 Fault 76 Driver 5 Overcurrent 2 PLD Clock Fail 30 Supervisor SW 5 Fault 77 Driver 6 Fault 9 Calibration Reset 31 Supervisor KSI Voltage Fault 78 Driver 6 Overcurrent 10 Main Brake Driver...

Страница 29: ...Main contactor fault failed to close Replace contactor 33 Supervisor DIR check fault Program issue If fault is on an external signal check that signal first If no problem with the external signal lik...

Страница 30: ...WD REV speed signal intermittent Check or replace 5K ohm potentiometer Difficult to steer Low tire pressure Check tire pressure Defective damper or steering rod Check or replace damper or steering rod...

Страница 31: ...TB12SE TB12PETUFFTRUK POWER BUGGY OPERATION MANUAL REV 0 04 01 22 PAGE 31 NOTES...

Страница 32: ...PAGE 32 TB12SE TB12PETUFFTRUK POWER BUGGY OPERATION MANUAL REV 0 04 01 22 ELECTRONIC COMPONENT LOCATOR 2 230v 110v 50Hz 60Hz 1 A D B C P H M J Y V I C1 G O B1 A1 Z N K W S E U X R Q F L T...

Страница 33: ...9 MOTOR CONTROLLER BLK WHT GRN GND CONNECT TO 120 VAC POWER SOURCE BLK YEL F BLK WHT K1 1 K1 2 M WHT J1 J1 0 5V IN NOTES BLUE SQUARE WHITE LETTERING DENOTES INTER CONNECTIONS POINTS BLACK CIRCLE WHITE...

Страница 34: ...ct at the time of approval for printing Illustrations descriptions references and technical data contained in this manual are for guidance only and may not be considered as binding Multiquip Inc reser...

Отзывы: