TB12SE/TB12PE TUFFTRUK POWER BUGGY• OPERATION MANUAL — REV. #0 (04/01/22) — PAGE 27
MAINTENANCE
AGM BATTERY CHARGING
To maximize the life of your AGM battery (), it is important
that it is properly charged. As with all lead-acid batteries,
both over- and under-charging an AGM battery will result
in
shortened service life
. The AGM batteries are sealed
for life units and do not require any fluid top up.
Figure 32. Battery Series Connections
The TB12SE and TB12PE power buggies are equipped with
an on-board SMART charger (Figure 33) which maintains
the battery full charge condition without resulting in over
charging.
Figure 33. Battery Charger
POSITIVE
JUMPER
RED
NEGATIVE
BLACK
BATTER
Y 1
12 VOL
T
BA
TTER
Y 2
12 VOL
T
24 VDC TOTAL
SERIES CONNECTION
Charging System Inspection
The charger's AC power cord should be free of breaks
or cuts and the wall plug socket should be clean and
free from debris.
The cable connectors from the on-board charger should
be clean and properly mate with the battery terminals to
ensure a sound connection.
Battery Inspection
Check battery cables are not damaged.
Connectors should be free of corrosion.
Make sure battery cable post or eyelet connectors are
tight to avoid arcing.
Charging Guidelines
When the batteries have been discharged to
¼ full
as
indicated on the battery gauge it is time to have the
batteries fully charged. Plug the on-board battery charger
power cord into a 120 VAC power outlet.
Allow batteries to complete a full charge and
do not
disconnect until fully charged
. Once fully charged, the
on-board
SMART
battery charger will indicate a
GREEN
status light indicating that the batteries are fully charged.
DO NOT
charge batteries i.e. if the batteries have only
discharged to
¾ full
as indicated on the battery gauge.
There is no need to connect the battery charger power
cable to the AC power outlet.
It is recommended to use the buggy until the batteries
have discharged to
¼ full
as indicated on the battery
gauge, then place the batteries into a full charge cycle.
ALWAYS
charge batteries in a well ventilated area as
gasses (fumes) may be released through the pressure
relief valve if the batteries are excessively over-charged.
NEVER
charge a frozen battery.
Ideal charging temperatures: 32°F to 104°F (0°C to 40°C)
NOTICE
The charging light is normally
ORANGE
which changes
to
GREEN
when the batteries are fully charged
.