14
Conforms to UL Std. 61010-1, 61010-2-030, 61010-2-033
Certified to CSA Std. C22.2 No. 61010-1, 61010-2-030, IEC std.
61010-2-033.
3.3.6. DIODE TEST
Forward current: 1mA
dc
environ.
Reverse voltage: 3 V
dc
environ.
Function
Resolution
Display
1mV
The display unit indicates the reverse voltage
of the diode.
3.3.7. CONTINUITY
Open-circuit voltage: 1 V
dc
environ.
The instrument emits an audible signal when the measurement is below
approximately 40Ω.
3.3.8. CAPACITY
Range
10 nF
100 nF
1 µF
10 µF
100 µF
1 mF
10 mF
Resolution
1 pF
10 pF
100 pF
1 nF
10 nF
100 nF
1 µF
Intrinsic
uncertainty
± (4% R ±
5 pt)
± (3% R ±3 pt)
3.3.9. TEMPERATURE
Measurement range
-20°C ... +1000°C
Resolution
1°C
Intrinsic uncertainty
±(3% R ±3 pt)
3.3. ENVIRONMENTAL CONDITIONS
Operating range: 0 to 40°C and
<
80%RH without condensation.
Storage range (without batteries): -10 to +60°C and
<
70%RH without
condensation.
If an extended period of non-use is anticipated, or for storage, withdraw the
batteries from the housing.
For use indoors and outdoors without rain.
Pollution degree: 2.
Altitude: <2000m.
3.4. POWER SUPPLY
The instrument is powered by three 1.5V alkaline batteries (type AAA or LR3).
3.5. CHARACTERISTICS OF CONSTRUCTION
Dimensions (L x l x P)
206 x 79 x 43mm
Clamping diameter
26mm
Mass
270g approx.
Drop test
2m.
3.6. ELECTRICAL SAFETY
Electrical safety 600V CAT III per IEC 61010-1, IEC 61010-032 and IEC
61010-033.
3.7. ELECTROMAGNETIC COMPATIBILITY
Emission and immunity in industrial environment according to IEC 61326-1.