use with solid fuel appliances) is therefore recommended where the young, elderly or infirm are
concerned.
NOTE:
The larger of the units manufactured have gas consumption similar to that of a small
boiler (i.e.50000 BTU). Therefore, it is essential that the gas supply pipe work be of a size that will
allow for the correct flow rate (See
TECHNICAL DATA
for required information). Ideally the 8mm
connection pipe to the burner should be as short as possible and the maximum length should not
be greater than 1mtr. Also ensure that the isolating tap does not have a reduced bore.
NOTE:
The Box used with this appliance will become hot during use. Care should be taken
when operating the controls.
SECTION 2
TECHNICAL DATA
GAS TYPE G20 at 20
mbar
CATEGORIES
I
2H
HEAT INPUT (GROSS kW )
6.95
FLOW RATE (m
3
/h)
0.65
WORKING ‘’P’’ (mbar)
20
BURNER TEST ‘’P’’(mbar)
9.3
REMOTE VALVE
GV60
PILOT OXY DEPLETION DEVICE
OP9039
ONE I NJECTOR
16/650
APPLIANCE MASS (kg)
6.0
DATA LABEL AFFIXED
TO BURNER TRAY
NOTE:
This size is rated below 7kw, therefore no vent is required if flue flow for the clearance
of the products of combustion is correct.
NOTE:
This appliance is to be used with a class 1 flue (7” diameter).
INSTALLATION PARAMETERS
SECTION 3 – REGULATIONS AND CODE OF PRACTICE
3.1
In your own interest and safety it is law that all gas appliances are installed by a
competent person, in accordance with the current Gas Safety (Installation and Use)