• Always use a certified safety cable that can hold 12 times the weight of
the unit when installing the unit. This secondary safety attachment should
be installed in a way that no part of the unit can drop more than 8” (20cm)
if the main attachment fails.
• Never stand directly below the device when mounting, removing, or servicing
the fixture.
• The installation should be inspected every year by a skilled person to
ensure safety.
• Be sure to comply with the cooling requirements of the unit.
Making AC Power Connections
Risk of fire / Safety risk
• The Multispot HP5-70 requires an AC power source with sufficient
power and correct grounding to ensure safe operation. The
AC power source must be equipped with a circuit breaker. Make sure
to only use compliant AC supply lines.
• The Multispot HP5-70 has an AC outlet that is designed to carry
loads of no more than 10A. Make sure that all connected units in a
chain fed by the first unit do not exceed a maximum of 10A current
consumption.
• When using powerCON jumpers to daisy chain units using the
powerCON outlet, do not connect more than 12 units together.
• Do not disconnect the unit from AC power using the powerCON
connector. The powerCON is a connector without breaking
capacity, i.e. the powerCON should not be connected or disconnected
under load or when live.
To connect the unit to AC power, first plug the cable into the unit. Align the tabs on the
powerCON input connector (blue) with the slots in the powerCON inlet (blue) and insert
connector until it stops, then rotate the connector clockwise until the silver tab clicks
into place and locks the connector in. If using powerCON jumpers to daisy chain power
across multiple units using the powerCON outlet, connect all units, up to 12, together
before connecting the first unit to AC power. Align the tabs on the powerCON output
connector (grey) with the slots in the powerCON outlet (grey) and insert connector until
it stops, then rotate the connector counterclockwise until the silver tab clicks into place
and locks the connector in. Once all units are connected together, the first unit may be
connected to AC power.
To remove the power cables from the units, first disconnect the first unit from AC power.
Grasp the powerCON input connector (blue), slide the silver tab back, and rotate the
connector counterclockwise until it stops, then pull the connector straight out of the
powerCON inlet. Grasp the powerCON output connector (grey), slide the silver tab
back, and rotate the connector clockwise until it stops, then pull the connector straight
out of the powerCON outlet.
NOTE:
The powerCON is a connector without breaking capacity, i.e. the powerCON
should not be connected or disconnected under load or when live.
Making DMX Control Connections
Connect the Multispot HP5-70 to a suitable DMX controller where needed, and
interconnect several units by means of their DMX In/Outputs as required. The last unit shall
be fitted with a proper 120 Ohm termination resistor-equipped DMX-plug as shown in below
drawing. Please make sure that all used DMX cables comply with below standard:
Termination
1 MODE selection Button
2 LEFT ARROW Button
3 RIGHT ARROW Button
4 – Button
5 + Button
6 DISPLAY: Sound-to-Light
Indicator
7 DISPLAY: 4-Digit Message
Display Area
8 DISPLAY: + Indicator
9 DISPLAY: - Indicator
10 DISPLAY: ARROW Indicators
11 DISPLAY: DMX Signal
Presence Indicator
12 Microphone
cover membrane
13 DMX Input
14 DMX Output
15 AC Power Input
16 AC Power Output
17 M6 safety lug
mounting thread
18 M10 nut insert point
User Interface
Overview:
Operation
User interface