“RSET” Reset –

 Press the left/right buttons (2 or 3) until the display shows “RSET”.  

Press the +/- buttons (4 or 5) to change the display to “YES+”.  Pressing the + button (4) 
will perform a factory reset.  This returns all the settings and calibration to the defaults.  
This does not include the operation hours.  

“HOUR” Operation Hours – 

Press the left/right buttons (2 or 3) until the display 

shows “HOUR”.  Press the +/- buttons (4 or 5) to show the number of hours of operation.  
The unit can only display the hours up to 9999.

“VERS” Software Version –

 Press the left/right buttons (2 or 3) until the display 

shows “VERS”.  Press the +/- buttons (4 or 5) to show the software version. 

 Maintenance

This device does not need regular maintenance. It the unit fails to operate, return the 
unit to Apollo for service.  There are no user serviceable parts inside.  The glass front 
may be cleaned using a glass cleaner. 

 Technical Data Multispot HP5-70

Output

2600 lm

LEDs, Total 

34

LEDs, Red

8×1W

LEDs, Green

6×3W

LEDs, Blue

6×3W

LEDs, Amber

8×1W

LEDs, White

6×3W

Optics

Secondary, 25 degrees (40 optional)

DMX Channels

3-7

IP Rating

20 (as-is)/65 (with conversion kit)

Mains Input

AC90-250V~ 50/60Hz

Power supply type

Auto-switching

Power consumption

75W

Fuse

internal (see service manual)

DMX connections

5 pin XLR (Male / Female)

Modulation Type

Pulse Density Modulation (PDM)

Control protocol

DMX 512 (1990)

Dimensions (with straight bracket) HxWxD

13” (33cm) x 12.8” (32.5cm) x 6.2” (15.75cm)

Weight

14.8 lbs (6.7kg)

 Warranty

Items are covered for defects in materials and workmanship for one year, including repair 
parts and repair labor on defective item, from date of Apollo invoice.  The warranty covers 
freight for 30 days after initial purchase.  Apollo does not cover any other loss resulting from 
product failure.
Products being returned for warranty repair must display the original serial number sticker.  
Removal of the serial number sticker voids the product’s limited warranty.

  •  Despite the care taken for the compilation of this book, Apollo Design Technology, 

Inc.,  

    cannot be held responsible for any damages resulting from errors that may appear in
     this book.  All efforts have been made to provide the most accurate, up-to-date 
    instructions and illustrations possible.

  •  Need assistance?  Call Apollo at 800-288-4626 for details.

    Keep this information handy if requiring technical assistance.

Serial Number

Date Purchased

Purchased From

 Standards

This product complies with the following standards: 
EU electrical safety . . . . . . . . . . . . . . EN60598-1:2008, EN60598-2-1:1989
EU general safety  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  .  EN60598-2-17
EU photobiological safety     .   . .   .   . .   .   . .   .   . .   .   . .   .   . .   .   . .   .   EN 62471:2008
EU EMC.  .   .   .  .   .   .  .   .   .  .   EN55015: 2006 + A1:2007, EN61547:1995 + A1:2000
EU Harmonics . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN61000-3-2:2006
EU Flicker     .   . .   .   . .   .   . .   .   . .   .   . .   .   . .   .   . .   .   . .   .   . .   .   . . EN61000-3-3:2008
US safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UL60065
US EMC.  .   .   .  .   .   .  .   .   .  .   .   .  .   .   .  .   .   .  .   .   .  .   .   .  .   .   .  .   .   .  .   .   .  .   .FCC Part 15

This product meets both the EMC Directive 2004/108/EC and the Low Voltage 
Directive 2006/95/EC.

Содержание HP5-70

Страница 1: ...m Smart Color PRO Scrollers Smart Move Rotators Smart Move Vertical Smart Power Power Supplies EZ Iris DMX Spotlight Mini Architectural Luminaires Tape Dichroics Pattern Holders Cable 4130 Fourier Dr...

Страница 2: ...rom all product liability Symbols used in this manual The following symbols are used to identify important safety information on the product and in this manual WARNING Read manual before installation...

Страница 3: ...Use a smooth and dry cloth only for cleaning 4 Do not submerge unit in liquid 5 If unit is not converted to comply with IP65 rating do not expose this unit to any dripping or splashing liquids and do...

Страница 4: ...lugs 1 power cable IP20 unit only If any part is missing please contact your dealer immediately for replacement 6 6 Getting started IP65 version only Making Internal Connections Your Multiform HP5 70...

Страница 5: ...diameter or with insufficient flexibility of its outer jacket may defeat the IP65 rating of the fixture and may void any warranty NOTE If opting to not install cable in all 4 PG9 glands it is necessar...

Страница 6: ...dry and has cooled down for at least 30 minutes after last operation The unit should be at room temperature The location chosen to exchange the lens panel does not have more than 40 relative humidity...

Страница 7: ...nvection to its outside metal case Do not Operate the Multispot HP5 70 in environments with more than 105 F 40 C environmental temperature Operate the Multispot HP5 70 in any closed space unless force...

Страница 8: ...ross multiple units using the powerCON outlet connect all units up to 12 together before connecting the first unit to AC power Align the tabs on the powerCON output connector grey with the slots in th...

Страница 9: ...5 warm ST11 Lavender ST24 Light Orange ST12 Hot Pink ST25 Dark Orange SP Switch Strobe Patterns Mode In this mode you will only find hard switching and strobe patterns Press the MODE button 1 until th...

Страница 10: ...unction DMX channel Value Range Function 1 000 010 Red 1 154 163 Light Purple 011 020 Green 164 174 Light Lavender 021 030 Blue 175 184 Light Blue 031 040 Yellow 185 194 White 1 cool 041 051 Pink 195...

Страница 11: ...When in DMX mode the first unit will determine the DMX mode and addresses of the units The desired DMX mode and starting address needs to be set on the first unit prior to using this feature Press th...

Страница 12: ...Pulse Density Modulation PDM Control protocol DMX 512 1990 Dimensions with straight bracket HxWxD 13 33cm x 12 8 32 5cm x 6 2 15 75cm Weight 14 8 lbs 6 7kg Warranty Items are covered for defects in m...

Отзывы: