Multiform HP5-70 Скачать руководство пользователя страница 3

Exclusive U.S. Distributor

3

3

 

WARNING!

 

Fire hazard.

 

WARNING! 

LED light emission. Risk of eye injury. 

  

  Security Advice Before Use

 

General advice:

 

1.

 

Read this manual completely before using the product.

 

2.  Keep this manual in your records for future reference.

 

3.  Follow all instructions printed in this manual, otherwise 

 

  warranty may become void. 

 

4.  Follow all printed safety advice on the device. 

 

5.  Carry this product with care.  Dropping or heavy vibration may 

 

  damage this product mechanically and/or electrically.

 

6.  The manufacturer and distributor take no responsibility for injury  

 

  or damage caused by not following the safety precautions and  

 

  instructions printed within this manual and on the device.

Protection From Eye Injury 

 

1.  Warning: Depending on the configuration of the device, this device  

 

  reaches the limits of IEC/EN62471 Group 2 and may extend into  

 

  Group 3. 

 

2.  To avoid eye injury, do not look into the beam from a distance    

 

  of less than 28’ (8.5m) from the front surface of the fixture without  

 

  protective eyewear such as shade-5 welding goggles.  At greater  

 

  distances, light output is harmless to the naked eye provided that  

 

  the eye’s natural aversion response is normal.

 

3.  Do not view the beam directly with optical instruments such as 

 

  magnifiers, telescopes, binoculars or similar optical instruments 

 

  that may concentrate the light output.

 

4  Ensure that during setup and DMX programming, no persons are  

 

  within 28’ (8.5m) of the device’s front surface to avoid accidental  

 

  exposure to the light beam.

Protection From Electric Shock:

 

1.  Only connect this unit to a mains socket outlet with protective earth  

 

  connection, ground-fault (earth-fault) and overload protection. 

 

2.  When removing the AC power cord from an AC power outlet, grip  

 

  the plug.  Never pull on the cable only.  To disconnect the unit from  

 

  AC power, remove the AC power cord from the AC power outlet.   

 

  Do not disconnect the unit from AC power using the powerCON   

 

  connector.  The powerCON is a connector without breaking 

 

  capacity, i.e. the powerCON should not be connected or 

 

  disconnected under load or when live.

4

4

 

3.  Disconnect the unit from AC power before cleaning.  

 

  Use a smooth and dry cloth only for cleaning. 

 

4.  Do not submerge unit in liquid.

 

5.  If unit is not converted to comply with IP65 rating, do not expose  

 

 

  this unit to any dripping or splashing liquids, and do not place  

 

  objects filled with liquids, such as vases, on the unit.  Do not operate  

 

  this unit near open water or in high humidity. 

 

6.  Choose the position of the AC cord according to the lowest risk of    

 

  damage by foot traffic or rolling equipment. 

 

7.  Do not open the unit for service.  There are no user-serviceable  

 

 

  parts inside.  Warranty will be void in any case of unauthorized  

 

 

  service by the user or other unauthorized persons. 

Protection From Fire:

 

1.  Take care to not place the unit near sources of heat (e.g. powerful    

 

  amplifiers, fog machines).

 

2.  Allow at least 6” (15cm) between this unit and other devices or walls  

 

  to allow for proper cooling.

 

3.  Take care to allow sufficient air convection in the unit’s environ 

 

 

  ment to avoid overheating.  Make sure air convection slots are not    

 

  blocked.  Do not operate this unit in environmental temperatures  

 

 

  exceeding 105°F (40°C). 

 

4.  Be sure unit is kept at least 30” (76cm) away from any flammable    

 

 materials. 

 

5.  Do not attach gel or diffusion directly to the LEDs or the front of 

 

  the unit. 

 

6.  To avoid overloading power, check the total maximum power of your  

 

  AC wall outlet if you are using powerCON jumpers to daisy chain    

 

  units together.

 

7.  When using powerCON jumpers to daisy chain units using the 

 

  powerCON outlet, do not connect more than 12 units together.

Protection From Injury and Damage:

 

1.  Never use any accessories or modifications not authorized by the    

 

  manufacturer of this unit.

 

2.  Choose a location for operation where the unit is protected from  

 

 

  vibration and where a fixed mounting position is provided.  In case of 

 

  overhead-mounting, follow applicable rigging rules and regulations  

 

  for rigging safety, including the use of an approved safety cable. 

 

3.  The surface of the device may get hot during operation.  Do not  

 

 

  touch heat sink areas of the device during operation.  Allow 30  

 

 

  minutes of cool-down time after powering off before touching.

 

4.  If fluids have spilled into the unit when configured to IP20,  

 

  immediately disconnect power to the unit and return the unit to  

 

 

  Apollo for service.

 

5.  This unit has no user serviceable parts.  If service is needed, return   

 

  unit to Apollo for service.

Содержание HP5-70

Страница 1: ...m Smart Color PRO Scrollers Smart Move Rotators Smart Move Vertical Smart Power Power Supplies EZ Iris DMX Spotlight Mini Architectural Luminaires Tape Dichroics Pattern Holders Cable 4130 Fourier Dr...

Страница 2: ...rom all product liability Symbols used in this manual The following symbols are used to identify important safety information on the product and in this manual WARNING Read manual before installation...

Страница 3: ...Use a smooth and dry cloth only for cleaning 4 Do not submerge unit in liquid 5 If unit is not converted to comply with IP65 rating do not expose this unit to any dripping or splashing liquids and do...

Страница 4: ...lugs 1 power cable IP20 unit only If any part is missing please contact your dealer immediately for replacement 6 6 Getting started IP65 version only Making Internal Connections Your Multiform HP5 70...

Страница 5: ...diameter or with insufficient flexibility of its outer jacket may defeat the IP65 rating of the fixture and may void any warranty NOTE If opting to not install cable in all 4 PG9 glands it is necessar...

Страница 6: ...dry and has cooled down for at least 30 minutes after last operation The unit should be at room temperature The location chosen to exchange the lens panel does not have more than 40 relative humidity...

Страница 7: ...nvection to its outside metal case Do not Operate the Multispot HP5 70 in environments with more than 105 F 40 C environmental temperature Operate the Multispot HP5 70 in any closed space unless force...

Страница 8: ...ross multiple units using the powerCON outlet connect all units up to 12 together before connecting the first unit to AC power Align the tabs on the powerCON output connector grey with the slots in th...

Страница 9: ...5 warm ST11 Lavender ST24 Light Orange ST12 Hot Pink ST25 Dark Orange SP Switch Strobe Patterns Mode In this mode you will only find hard switching and strobe patterns Press the MODE button 1 until th...

Страница 10: ...unction DMX channel Value Range Function 1 000 010 Red 1 154 163 Light Purple 011 020 Green 164 174 Light Lavender 021 030 Blue 175 184 Light Blue 031 040 Yellow 185 194 White 1 cool 041 051 Pink 195...

Страница 11: ...When in DMX mode the first unit will determine the DMX mode and addresses of the units The desired DMX mode and starting address needs to be set on the first unit prior to using this feature Press th...

Страница 12: ...Pulse Density Modulation PDM Control protocol DMX 512 1990 Dimensions with straight bracket HxWxD 13 33cm x 12 8 32 5cm x 6 2 15 75cm Weight 14 8 lbs 6 7kg Warranty Items are covered for defects in m...

Отзывы: