“FP” Fade Patterns Mode

In this mode you will only find soft fade patterns.  Press the MODE button (1) until the 
first two digits on the display shows “FP”.  Choose a pattern, “FP 0” – “FP 7”, by pressing 
the left/right buttons (2 or 3), see table below.

The +/- buttons (4 or 5) change the color fade speed, “SL 0” – “SL25”.  Pressing the 
+/- buttons (4 or 5) once shows the current setting.  The setting can then be changed 
by using the +/- buttons (4 or 5), see table below.  The display will automatically return 
to show “FP##” after 5 seconds, and the speed setting will remain as set.

NOTE: 

This mode is automatically disabled when an external DMX signal is present.

#

Pattern

#

Pattern

FP 0

Red - Green

FP 4

Hot Pink - Lime

FP 1

Green - Blue

FP 5

Pink - Blue

FP 2

Blue - Red

FP 6

Turquoise - Pink

FP 3

Red - Yellow

FP 7

Red - Green - Blue (All Colors)

Setting

Speed

Setting

Speed

SL 0

1 loop per 960 seconds

SL13

1 loop per 3 seconds

SL 1

1 loop per 480 seconds

SL14

1 loop per 2 seconds

SL 2

1 loop per 360 seconds

SL15

1 loop per 1.5 seconds

SL 3

1 loop per 240 seconds

SL16

1 loop per 1.25 seconds

SL 4

1 loop per 120 seconds

SL17

1 loop per 1 second

SL 5

1 loop per 80 seconds

SL18

1.2 loops per second

SL 6

1 loop per 40 seconds 

SL19

1.4 loops per second

SL 7

1 loop per 20 seconds 

SL20

1.6 loops per second

SL 8

1 loop per 12 seconds

SL21

1.9 loops per second

SL 9

1 loop per 10 seconds 

SL22

2.2 loops per second

SL10

1 loop per 8 seconds

SL23

2.5 loops per second

SL11

1 loop per 6 seconds

SL24

2.8 loops per second

SL12

1 loop per 4 seconds

SL25

3.2 loops per second

“SLA” DMX Slave Mode

The Slave mode offers 4 independent groups of slaves. Press the MODE button (1) until 
the first three digits on the display shows “SLA”.  The +/- buttons (4 or 5) change the slave 
group, “SLA1” – “SLA4”.  The first unit will then control any connected units.  Each slave 
group will be in the same preset and speed as the master, but the timing of the preset 
will be offset from the previous slave group.  To have all units operating together, set all 
units to slave group 1.

DMX 

channel

Value 

Range

Function

DMX 

channel

Value 

Range

Function

1

000-010

Red

1

154-163

Light Purple

011-020

Green

164-174

Light Lavender

021-030

Blue

175-184

Light Blue

031-040

Yellow

185-194

White 1 (cool)

041-051

Pink

195-204

White 2

052-061

Turquoise

205-215

White 3

062-071

Lime

216-225

White 4

072-081

Orange

226-235

White 5 (warm)

082-092

Marine

236-245

Light Orange

093-102

Blue Green

246-255

Dark Orange

103-112

Lavender

2

000-255

Intensity

113-122

Hot Pink

3

000-049

Static Colors

123-133

Flesh

4

000-014

Strobe off

134-143

Light Blue Green

015-255

Strobe on

144-153

Light Green

 

 

 

“GDMX” General DMX Mode

Press the MODE button (1) until the display shows “GDMX”.  When the unit is receiving a 
DMX signal, the DMX indicator (11) will be illuminated.

Setting the DMX Address

The +/- buttons (4 or 5) change the DMX address, “   1” – “ 512”.  Pressing the +/- buttons 
(4 or 5) once shows the current DMX address.  The DMX address can then be changed 
by using the +/- buttons (4 or 5).  Holding the +/- buttons (4 or 5) for longer than 1 
second accelerates the change rate of the displayed value to 3 times normal speed.  The 
display will automatically return to show “GDMX” after 5 seconds, and the DMX address 
will remain as set.  The DMX address remains the same regardless of the selected DMX 
control mode.  However, the number of channels used may change depending on the 
selected DMX control mode.

Selecting a DMX Control Mode

Pressing the left/right buttons (2 or 3) once shows the current DMX control mode.  The 
left/right buttons (2 or 3) can then be used to cycle through the following DMX control 
modes.

“3RAW”  3 Channels – 1=Red, 2=Green, 3=Blue

“3CCC”  4 Channels – 1=Red, 2=Green, 3=Blue, 4=Intensity/Strobe

    – CH 4 values – 000-127=Intensity, 128-239=Strobe, 240-255=Full Intensity

“3CMS”  5 Channels – 1=Red, 2=Green, 3=Blue, 4=Intensity, 5=Strobe

“5RAW”  5 Channels – 1=Red, 2=Green, 3=Blue, 4=Amber, 5=White

“5CMS”  7 Channels – 1=Red, 2=Green, 3=Blue, 4=Amber, 5=White,  

 

   

6=Intensity, 7=Strobe

“HSLS”  4 Channels – 1=Hue, 2=Saturation, 3=Lightness, 4=Strobe

“PRES”  4 Channels – Presets, see section below.

When the DMX control mode is set to Presets, the DMX value of channel 3 determines 
which presets channel 1 controls.  If the DMX value of channel 3 is 000-049, channel 
1 selects static colors, see table below.  Channel 4 strobe speed is 015=slow (1Hz) to 
255=fast (18Hz).

Содержание HP5-70

Страница 1: ...m Smart Color PRO Scrollers Smart Move Rotators Smart Move Vertical Smart Power Power Supplies EZ Iris DMX Spotlight Mini Architectural Luminaires Tape Dichroics Pattern Holders Cable 4130 Fourier Dr...

Страница 2: ...rom all product liability Symbols used in this manual The following symbols are used to identify important safety information on the product and in this manual WARNING Read manual before installation...

Страница 3: ...Use a smooth and dry cloth only for cleaning 4 Do not submerge unit in liquid 5 If unit is not converted to comply with IP65 rating do not expose this unit to any dripping or splashing liquids and do...

Страница 4: ...lugs 1 power cable IP20 unit only If any part is missing please contact your dealer immediately for replacement 6 6 Getting started IP65 version only Making Internal Connections Your Multiform HP5 70...

Страница 5: ...diameter or with insufficient flexibility of its outer jacket may defeat the IP65 rating of the fixture and may void any warranty NOTE If opting to not install cable in all 4 PG9 glands it is necessar...

Страница 6: ...dry and has cooled down for at least 30 minutes after last operation The unit should be at room temperature The location chosen to exchange the lens panel does not have more than 40 relative humidity...

Страница 7: ...nvection to its outside metal case Do not Operate the Multispot HP5 70 in environments with more than 105 F 40 C environmental temperature Operate the Multispot HP5 70 in any closed space unless force...

Страница 8: ...ross multiple units using the powerCON outlet connect all units up to 12 together before connecting the first unit to AC power Align the tabs on the powerCON output connector grey with the slots in th...

Страница 9: ...5 warm ST11 Lavender ST24 Light Orange ST12 Hot Pink ST25 Dark Orange SP Switch Strobe Patterns Mode In this mode you will only find hard switching and strobe patterns Press the MODE button 1 until th...

Страница 10: ...unction DMX channel Value Range Function 1 000 010 Red 1 154 163 Light Purple 011 020 Green 164 174 Light Lavender 021 030 Blue 175 184 Light Blue 031 040 Yellow 185 194 White 1 cool 041 051 Pink 195...

Страница 11: ...When in DMX mode the first unit will determine the DMX mode and addresses of the units The desired DMX mode and starting address needs to be set on the first unit prior to using this feature Press th...

Страница 12: ...Pulse Density Modulation PDM Control protocol DMX 512 1990 Dimensions with straight bracket HxWxD 13 33cm x 12 8 32 5cm x 6 2 15 75cm Weight 14 8 lbs 6 7kg Warranty Items are covered for defects in m...

Отзывы: