![multicomp pro MP720105 Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/multicomp-pro/mp720105/mp720105_manual_1854300083.webp)
4.Advanced User Guidebook
The following steps take oscilloscope with dual-channel AG for instance.
To clone waveform and save to the internal/USB memory:
(1) Push
Save
button.
(2) Select
Type
in the bottom menu, in the left menu, turn the
M
knob to select
Clone
.
(3) Select
Source
in the bottom menu, select one channel (
CH1
/
CH2)
or two
channels (
CH1&CH2
) in the right menu for Source.
(4) Select
Line
in the bottom menu. If
a
or
b
is selected, turn the
M
knob to move the
cursor. If
ab
is selected, turn the
M
knob to move the pair of cursors. If
x
is
selected, the entire screen will be selected automatically. The waveform
information is displayed at the left bottom corner of the screen.
Length
Frequency
Time
Note
: If "
Out Of Limits
" appears in the information or a message "
Waveform
points beyond the limit.
" appears on the screen, that means the length of the
cloned waveform exceeds the limit. When the source is CH1 or CH2, the
maximum length is 2M; When the source is CH1&CH2, the maximum length is
1M. Push the
Acquire
button, select
Length
in the bottom menu, and set the
record length to a smaller value.
(5) Select
Save
in the bottom menu.
To save the waveform to internal memory
, select
Storage
in the right menu
as
Internal
. Turn the
M
knob to select an object in the left menu, select
Save
in the right menu.
To save the waveform onto a USB memory device
, insert a USB memory
device into the port on the front panel. If the icon
appears on the top right
of the screen, the USB memory device is installed successfully. If the USB
memory device cannot be recognized, format the USB memory device
according to the methods in "
Storage
in the right menu as
External
. Select
Save
in the right menu. An input
keyboard used to edit the file name will pop up. The name is default as current
system date and time. Turn the
M
knob to select the keys, push the knob to
input. Select the
key in the keyboard to confirm. The cloned waveform
will be saved onto the USB memory device as a file with the ota suffix.
To output the cloned waveform in the internal memory
through the generator:
(The generator is optional.)
(1) Push
Save
button.
(2) Select
Type
in the bottom menu, in the left menu, turn the
M
knob to select
Clone
.
(3) Select
Save
in the bottom menu, select
Storage
in the right menu as
Internal
.
78
Содержание MP720105
Страница 1: ...i Digital Storage Oscilloscope Model MP720105 MP72016 MP72107...
Страница 40: ...4 Advanced User Guidebook Figure 4 2 Rectangle window Figure 4 3 Blackman window 35...
Страница 41: ...4 Advanced User Guidebook Figure 4 4 Hanning window Figure 4 5 Kaiser window 36...
Страница 68: ...4 Advanced User Guidebook Sine x x interpolation Linear interpolation 63...