![multicomp pro MP720105 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/multicomp-pro/mp720105/mp720105_manual_1854300021.webp)
3.Junior User Guidebook
1.
Turn the
Horizontal Scale
knob to change the horizontal time base setting and
observe the consequent status information change. Turn the
Horizontal Scale
knob to
change the horizontal time base, and it can be found that the
Horizontal Time Base
display in the status bar changes accordingly.
2.
Use the
Horizontal Position
knob to adjust the horizontal position of the signal in the
waveform window. The
Horizontal Position
knob is used to control the triggering
displacement of the signal or for other special applications. If it is applied to
triggering the displacement, it can be observed that the waveform moves horizontally
with the knob when you rotate the
Horizontal Position
knob.
Triggering displacement back to 0 shortcut key
Turn the
Horizontal Position
knob to change the horizontal position of channel and
push the
Horizontal Position
knob to set the
triggering displacement
back to 0 as a
shortcut key.
3.
Push the
Horizontal HOR
button to switch between the normal mode and the wave
zoom mode.
Introduction to the Trigger System
, there are one knob and three buttons make up
Trigger
Controls
.
The following practices will direct you to be familiar with the setting of the trigger system
gradually.
Figure 3-13 Trigger Control Zone
1.
Push the
Trigger Menu
button and call out the trigger menu. With the operations of
the menu selection buttons, the trigger setting can be changed.
2.
Use the
Trigger Level
knob to change the trigger level setting.
By turning the
Trigger Level
knob, the trigger indicator in the screen will move up
and down. With the movement of the trigger indicator, it can be observed that the
trigger level value displayed in the screen changes accordingly.
Note
: Turning the
Trigger Level
knob can change trigger level value and it is also
the hotkey to set trigger level as the vertical mid point values of the amplitude of the
trigger signal.
3.
Push the
Force
button to force a trigger signal, which is mainly applied to
the
"Normal" and "Single" trigger modes.
16
Содержание MP720105
Страница 1: ...i Digital Storage Oscilloscope Model MP720105 MP72016 MP72107...
Страница 40: ...4 Advanced User Guidebook Figure 4 2 Rectangle window Figure 4 3 Blackman window 35...
Страница 41: ...4 Advanced User Guidebook Figure 4 4 Hanning window Figure 4 5 Kaiser window 36...
Страница 68: ...4 Advanced User Guidebook Sine x x interpolation Linear interpolation 63...