Input power requirements:
At AC Transformer:
110 - 125 Volts AC Only; 50-60 Hz
At power jack on ATX-250:
12-15 Volts AC only
Power consumption Idle:
3 Watts
Ringing a device:
6-11 Watts
CO Interface:
Ren 1 .1 B
DOC (Canada)
Load No . 83
Input ring detection:
40-150 Volts AC; 15-68 Hz
DEVICE Interface:
Battery:
Nominal - 45 .5 Volt DC to devices 1 and 2
Off-hook detection:
3-150 ma
Ringer frequency:
33 Hz Pseudo-sinewave
Ringing no load:
Approximately 145 .6 Volts AC
Ringing 8000 ohm impedance
(REN 1.O):
Approximately 116 VAC
Ringing 4000 ohm impedance
(REN 2.0):
Approximately 98 VAC
Ringing 2667 ohm impedance
(REN) 3.0):
Approximately 83 VAC
Ringing short circuit:
current limited to 110 ma with ring trip .
(impedances less than
2667 ohms not recommended)
TECHNICAL