3 6
C O N F I G U R AT I O N
3 6
M U LT E N E T P O C K E T P A D
This can be used to block unwanted access to the
Serial Port data.
Active
- Application connects to a remote Host during the
bootup cycle. The ‘
Remote Host / IP Address
’ &
‘
Remote TCP Port
’ needs to be set.
Local TCP Port
-
The local TCP Port from which socket connections are made. Default
is 5000. Valid Port numbers are in the range: 502...65534.
Remote Host / IP Address - Must be set if ‘
Connection Type
’ is
Active
. TCP Socket
connections from this IP Address are initiated or accepted.
Default is ‘null’ (accept any Remote IP Address connection).
Remote TCP Port
- Must be set if ‘
Connection Type
’ is
Active
. TCP Socket
connections to this Remote Port are initiated or accepted.
Default is 0 (accept any Remote Port connection).
Application Protocol
-
Default is Raw.
Raw
- Data is streamed transparently through the
PocketPAD without any Protocol being used.
TC500
- Every message is prepended with a 4-byte
header (ASCII Most Significant Byte first)
specifying the length of the message according
to Burroughs TC500 Poll-Select.
Idle Timeout
- Disconnect the TCP connection after it has been idle for a
length of time. To keep the connection alive, set this value to
0 (default).
UDP Application Type
Use UDP/IP to transmit packets over the Ethernet network.
UDP Application Parameters overview:
Application Name -
This is the label you entered at the time of adding the Application.