Seite - 20 - Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95)
Data block MACHINE (Ma)
+----------------------------------------(Ma)
|
| Left:
| Displays the impulses/100 m taken
from
| a trailed machine, from the gearbox
v /-----------------/-----+ (cardan-shaft/wheel) or, if fitted ,
+-------------------------/-----------------/ | from the radar sensor
| I m p u l s e / 1 0 0 m | M e n u | T1 |---> Ms
|-------------------------|-----------------|------| If one of the sensors is not fitted,
| 0 I m p l . | C a l i b r a t | T2 |---------+ the corresponding rate "Impulses/100
m"
|-------------------------|-----------------|------| | must be set to 0.
| 4 7 0 G e a r b | | T3 | | The sensors have varying priorities
|-------------------------|-----------------|------| | The input "machine" has the highest
| 1 3 1 4 5 R a d a r | N e x t | T4 |---------------+ priority (e.g. Impulse taken from the
+-------------------------\-----------------\ | | | wheel of the field sprayer). In that
\-----------------\-----+ | | case the input gearbox and radar have
no
| | significance for the computer. Next
in
| | priority is the input "Radar".The
input
| | gearbox has the lowest priority.
| |
| | Right:
| | Press the T1 key for menu selection.
| | Press the T3 key for the calibration
| | Press the T4 key to proceed to the
next
| | display
| |
Description of the calibration process
for Impulses/100m
| |
v |
+-------------------------------------+ |
|
↑
|
v /-----------------/-----+ | |
+-------------------------/-----------------/ | | | Right:
| C a l i b r a t i o n | B a c k | T1 |---+ | | Press the T1 key to interrupt the
|-------------------------|-----------------|------| | | | calibration process.
| D r i v e e x a c t l | y 1 0 0 m | T2 | | | |
|-------------------------|-----------------|------| | | |
| t h e n s t o p a n |d p r e s s | T3 | | | | The calibration test can start.
|-------------------------|-----------------|------| | | |
| " i n p u t " | | T4 | | | |
+-------------------------\-----------------\ | | | |
| \-----------------\-----+ | | |
| | | |
After 1st impulse | | |
| | | |
v /-----------------/-----+ | | | After the first impulse from one of
the
+-------------------------/-----------------/ | | | | three possible sensors, the display
| C a l i b r a t i o n | | T1 | | | | shown on the left appears.
|-------------------------|-----------------|------| | | | The impulses are counted continually.
| 1 0 I m p l . | | T2 | | | | After 100 m you have to stop and to
|-------------------------|-----------------|------| | | | operate the input key "(=)". The
| 3 5 G e a r b | | T3 | | | | calibration test has to be carried
out
|-------------------------|-----------------|------| | | | on the field. For varying soil
| 0 R a d a r | | T4 | | | | conditions,separate calibration tests
+-------------------------\-----------------\ | | | | should be conducted. The rate
recorded
| \-----------------\-----+ | | | should be written down and if
required
| | | | altered via the keyboard.
After pressing the input key | | |
| | | |
|<------------------------------+ | |
|
↑
v
v /-----------------/-----+ | |
+-------------------------/-----------------/ | | | Left:
| I m p u l s ./ 1 0 0 m | M e n u | T1 |---> Ms | | After pressing the input key, the
|------------------------|------------------|------| | | recorded rate is displayed
| 2 1 0 I m p l | C a l i b r a t | T2 |---------+ |
|------------------------|------------------|------| | Right:
| 4 7 0 G e a r b | | T3 | | Press the T1 key for menu selection.
|------------------------|------------------|------| | Press the T3 key to repeat the
| 0 R a d a r | N e x t | T4 |-------------->| calibration test.
+-------------------------\-----------------\ | | Press the T4 key to proceed to the
next
\-----------------\-----+ | display
v