7.7
Detergent Cycle Switch
1.
With the rotary selector switch in the “Wash” position, press the “Detergent Cycle” switch once to
start the automatic wash cycle.
2.
The “Detergent Cycle” offers two programmable-cycle options:
• “Pre-Rinse—Rinse—Detergent—Post-Rinse”
(Standard and Japan program)
• “Pre-Rinse—Rinse—Detergent—Post-Rinse—Acid/Sanitize”
(Standard program only)
See Sections 5.8, 6.1, and 6.2 (43-57).
3.
The Pre-Rinse and Acid/Sanitize Cycles may be programmed for warm or cold fill water
temperature. See Sections 5.8, 6.1, and 6.2 (38-57).
4.
A programmable 45-minute delayed start is available to allow sufficient recovery time for the
water-heating device. See Sections 6.1 and 6.2 (58-62).
5.
To cancel and reset the “Wash Cycle,” turn the “Cool-Off-Wash” rotary switch to the “Off” position.
7.8
Acid Cycle Switch
1.
With the rotary selector switch in the “Wash” position, press the “Acid Cycle” switch once to start a
“Rinse—Acid” cycle. (Japan program starts a “Pre-Rinse—Hot Acid—Post-Rinse” cycle.) See Section
5.8, Chart 2.
2.
To cancel and reset the “Acid Cycle,” turn the “Cool-Off-Wash” rotary switch to the “Off” position.
7.9
Sanitize Cycle Switch
1.
With the rotary selector switch in the “Wash” position, press the “Sanitize Cycle” switch once to
start a “Sanitize” cycle. See Section 5.8, Chart 2.
2.
To cancel and reset the “Sanitize Cycle,” turn the “Cool-Off-Wash” rotary switch to the “Off”
position.
7.10
Agitate Sample Switch
1.
With the rotary selector switch on the “Off” position, press the “Agitate Sample” switch once to
start the agitator(s) for milk sampling. The agitator(s) will operate for the programmed period of 2,
5, or 10 minutes, and shut off automatically. See Sections 6.1 and 6.2 (31-37).
2.
To cancel “Agitate Sample” press the switch a second time.
7.11
Alarm Lamp
1.
The “Alarm Lamp” provides visual aid of the following alarm conditions:
a.
Flashing at 1
1
/
2
second intervals—The milk temperature is above a safe holding temperature.
b. Flashing at
1
/
2
second intervals—The milk temperature is below a safe holding temperature
and near freezing. (Call a Mueller Authorized Service Technician.)
c.
Constant illumination—Wash water did not enter the milk cooler within 2 minutes of a fill
cycle. (Call a Mueller Authorized Service Technician.)
2.
To test the “Alarm Lamp,” turn the rotary selector switch to the “OFF” position and press the
“Detergent Cycle” switch.
Sentry II with Auto-Dosing Assembly Operating Instructions
54
Effective April 1, 2000