2.8
Leveling the Milk Cooler
With the assistance of a floor jack and protective wooden-cradle block, level the milk cooler as
described in the following steps:
1.
Adjust the inner legs off the floor until the proper pitch is obtained with the four corner legs.
2.
Place a carpenter’s level across the brim of the manway opening and level the milk cooler by
adjusting the corner legs with a nylon strap wrench. Legs may be extended by turning the legs
counterclockwise, and retracted by turning the legs clockwise.
3.
Using the levels located on the side of the cooler, adjust each end of the milk cooler until the
proper height and pitch is obtained. (The milk cooler should pitch
1
/
4
" per foot towards the outlet
valve.)
4.
Using a certified seraphin, add the exact volume of water indicated for the “Set-Up Reading” on
the calibration chart.
5.
Adjust the final pitch of the milk cooler, matching the calibration gauge reading with the “Set-Up
Reading” on the calibration chart.
6.
When the front and back corner legs are positioned properly, the inner legs should be extended
firmly against the floor.
7.
Ensure that the final location and position complies with all regulations for the installation locality,
including the proper height of the milk outlet and the proper dimensions beneath and around the
milk cooler.
Figure 4 - Leveling the Milk Cooler
Sentry II with Auto-Dosing Assembly Operating Instructions
6