2.12
Pump Assembly and Electric Drain Installation
1.
Bolt the pump assembly and electric motor to the left front corner of the milk cooler as shown in
Figure 9.
2.
Trim the rubber elbow (Item 1) for proper fit and connect between the discharge fitting on the
pump assembly and the wash line in the milk cooler.
3.
Install the straight, liquid-tight conduit fitting (Item 2) in the stainless steel cover plate located on
the left side of the milk cooler.
4.
Thread the 3-wire cord (marked pump motor) through the conduit fitting and conduit (Item 3).
5.
Thread the plastic nut (Item 4) with the flat flange facing the motor onto the 90° liquid-tight fitting
(Item 5).
6.
Slip the neoprene gasket (Item 6) over the threads of the 90° liquid-tight fitting and thread the
assembly into the pump motor.
7.
Thread the 3-wire cord and conduit into the 90° liquid-tight fitting and secure with the liquid-tight
compression fitting.
8.
Wire the motor per the electrical schematic attached to the motor.
9.
Install the stainless steel screen (Item 7) in the rubber adapter (Item 8) and clamp the electric drain
valve in position with the two stainless steel hose clamps.
10. Install the cord grip (Item 9) in the stainless steel cover plate located on the left side of the milk
cooler.
11. Thread the cord (marked drain valve) through the cord grip and wire to terminal numbers 1 and 2
at the 24-vac electric drain valve coil.
12. Reattach the stainless steel cover plate and tighten all cord grips and liquid-tight conduit fittings.
Figure 9 - Pump Assembly and Electric Drain Installation
Sentry II with Auto-Dosing Assembly Operating Instructions
10
Effective April 1, 2000
Содержание SENTRY II
Страница 2: ......