21a. Indicator lamp of the air pressure in the rear brake circuit.
22. Indicator lamp of ET switching-on.
23. Indicator lamp of clogging of the pressure filter of the hydraulic system of mounted
equipment.
*
24. Indicator lamp of clogging of the pressure filter of the hydraulic system of steering
control.
25. Indicator lamp of oil overheating of the hydraulic system.
26. Indicator lamp of oil level fall in the tank of hydraulic system for control over turns and
service equipment.
27. Indicator lamp of switching on the battery master switch.
28, 32. Indicator lamp serviceability checkup buttons.
29. Indicator lamp of clogging of the engine air cleaner filter.
30. Indicator lamp of clogging of the engine oil filter.
31. Plug.
33. Indicator of fuel level in the tank.
34. The key is not involved.
35. Traffic headlight switch.
36. Switch of end out marker lamps on front and rear lights.
37. The key is not involved.
38. Turning-on of the heater fan.
39. Engine cooling fluid temperature gauge.
40. Alarm signaling switch.
41. Engine oil pressure gauge.
42. Indicator lamp of the emergency oil level of the engine (red).
43. Indicator lamp of the engine stop demand (red).
44. Indicator lamp of accumulator charge.
12
– Oil pressure gauge in GB
The oil pressure in the GB hydraulic system at the transmissions with the crankshaft rotation
speed of 900
–1,800 RPM shall be as follows:
1.0
–1.2 MPa (10–12 kgf/cm
2
)
– for K-744R1, K-744R2 tractors;
1.1
–1.3 MPa (11–13 kgf/cm
2
)
– for K-744R3, K-744R4 tractors.
The oil pressure growth on each transmission shall be fast. The pressure on neutraland in
engagement of synchroniser brake shall not be less than on transmission gears.
In case of pressure fall in GB below 10 kgf/cm
2
for K-744R1, K-744R2 tractor and below
11 kgf/cm
2
for K-744R3, K-744R4 tractors, a sound alarm will get operated in the intermittent
mode 30 s later.
14
– The air pressure gauge in the first circuit of the pneumatic system with built-in alarm
signaling of the minimum limit value of 0.45 MPa (4.5 kgf/cm
2
)
The air pressure in the pneumatic system in the process of operation shall be equal to 0.65
–
0.8 MPa (6.5
–8 kgf/cm
2
).
*
** It is allowed to switch on the indicator lamp of clogging of the pressure filter of the hydraulic system of steering
control for a short period of time until the operating oil temperature of the hydraulic system reached ~40
–50°С.
Содержание K-744R1
Страница 2: ...MTZ KIROVETS tractors K 744R1 K 744R2 K 744R3 K 744R4 2...
Страница 107: ...KIROVETS K 744R1 K 744R2 K 744R3 K 744R4 tractors 107 Driving shaft friction clutch I...
Страница 109: ...KIROVETS K 744R1 K 744R2 K 744R3 K 744R4 tractors 109 Driving shaft friction clutches II and III...
Страница 111: ...KIROVETS K 744R1 K 744R2 K 744R3 K 744R4 tractors 111 Driving shaft friction clutch IV...