1.4520.589 – MIC5 IPE Primary Open Cylinder 20
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 20 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.590 – MIC5 IPE Prim Short Circuit Cyl 1
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 1 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.591 – MIC5 IPE Prim Short Circuit Cyl 2
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 2 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.592 – MIC5 IPE Prim Short Circuit Cyl 3
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 3 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.593 – MIC5 IPE Prim Short Circuit Cyl 4
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 4 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.594 – MIC5 IPE Prim Short Circuit Cyl 5
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 5 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
1.4520.595 – MIC5 IPE Prim Short Circuit Cyl 6
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 6 in firing order.
1. Check cabling to ignition coil.
2. Check ignition coil.
MS15027/02E 2015-04
| Troubleshooting | 85
TIM-ID: 0000044566 - 002