1.4510.198 – Knock Sensor Error A7
Red alarm. Initiated by antiknock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.199 – Knock Sensor Error A8
Red alarm. Initiated by antiknock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.200 – Knock Sensor Error A9
Red alarm. Initiated by antiknock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.201 – Knock Sensor Error A10
Red alarm. Initiated by antiknock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.202 – Knock Sensor Error B1
Red alarm. Initiated by antiknock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
1.4510.203 – Knock Sensor Error B2
Red alarm. Initiated by antiknock control.
Cause
Corrective action
No signal from this knock
sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
MS15027/02E 2015-04
| Troubleshooting | 75
TIM-ID: 0000044566 - 002