204 – SD Level Lube Oil
Red alarm. Engine stop.
Associated parameter 1.8004.602
Cause
Corrective action
Engine oil level sensor defective,
short circuit or wire break.
u
Check sensor and cabling (B24), replace as necessary. Fault is
rectified following engine restart.
206 – SD T-Exhaust A
Yellow alarm.
Associated parameter 1.8004.576
Cause
Corrective action
Exhaust temperature sensor on
A side defective, short circuit or
wire break.
u
Check sensor and cabling (B4.21), replace if necessary. Fault is
rectified following engine restart.
207 – SD T-Exhaust B
Yellow alarm.
Associated parameter 1.8004.577
Cause
Corrective action
Exhaust temperature sensor on
B side defective, short circuit or
wire break.
u
Check sensor and cabling (B4.22), replace if necessary. Fault is
rectified following engine restart.
211 – SD P-Lube Oil
Red alarm. Engine stop.
Associated parameter 1.8004.563
Cause
Corrective action
Engine oil pressure sensor after
filter defective, short circuit or
wire break.
u
Check sensor and cabling (B5.1), replace as necessary. Fault is
rectified following engine restart.
212 – SD P-Coolant
Red alarm.
Associated parameter 1.8004.564
Cause
Corrective action
Coolant pressure sensor after
engine defective, short circuit or
wire break.
u
Check sensor and cabling (B16.1), replace if necessary. Fault is
rectified following engine restart.
MS15027/02E 2015-04
| Troubleshooting | 121
TIM-ID: 0000044567 - 003