1031 – LOLO P-Crankcase
Red alarm.
Associated parameter 2.0106.936
Cause
Corrective action
Crankcase pressure too low
(limit value 2). Restrictor valve in
crankcase breather too widely
open, faulty air filter.
1. Check air filter for damage, replace if visibly damaged.
2. Check setting of BlowBy restrictor valve.
MS15027/02E 2015-04
| Troubleshooting | 149