187 – AL CAN1 Error Passive
Yellow alarm.
Associated parameter 2.0500.687
Cause
Corrective action
CAN controller 1 has indicated a
warning. Bus nodes (ECU, SAM
or EMU) are faulty.
u
Check operation of nodes and cabling.
188 – AL CAN2 Bus Off
Yellow alarm.
Associated parameter 2.0500.688
Cause
Corrective action
CAN controller 2 is in “Bus-Off”
status. Automatic switching to
CAN bus 1. Bus nodes (ECU,
SAM or EMU) faulty.
u
Check operation of nodes and cabling.
189 – AL CAN2 Error Passive
Yellow alarm.
Associated parameter 2.0500.689
Cause
Corrective action
CAN controller 2 has indicated a
warning. Some reasons are, for
example, no corresponding
node, minor malfunctions or
temporary bus overload.
u
Check operation of nodes and cabling.
190 – AL EMU Parameter Not Supported
Red alarm.
Associated parameter 2.0500.690
Cause
Corrective action
EMU parameters are not
supported.
u
Contact Service (configuration fault).
201 – SD T-Coolant
Red alarm. Engine stop.
Associated parameter 1.8004.570
Cause
Corrective action
Coolant temperature sensor at
engine outlet defective, short
circuit or wire break.
u
Check sensor and cabling (B6.1), replace if necessary. Fault is
rectified following engine restart.
120 | Troubleshooting | MS15027/02E 2015-04
TIM-ID: 0000044567 - 003