Fault code no. Description
Meaning
Action
No. of as-
sociated
parameter
466
SD T-AUX 2
SD alarm configuration; ana-
log input for Aux 2 tempera-
ture defective; short circuit
or wire break
Check temperature
sensor and wiring,
replace as necessa-
ry. Fault is cleared
when engine re-
started.
1.8004.58
6
467
L2 T Aux 1
Alarm configuration limit 2;
preliminary warning: Aux 1
temperature signal above/
below limit 2, depending on
configuration.
Determine cause of
limit violation and
rectify fault.
2.0130.92
2
468
SD T-AUX 1
SD alarm configuration; ana-
log input for Aux 1 tempera-
ture defective.
Replace engine
governor.
1.8004579
469
SD AUX 1
SD alarm configuration; ana-
log input signal for Aux 1 de-
fective; short circuit or wire
break
Check signal trans-
mitter and wiring,
replace as necessa-
ry. Fault is cleared
when engine re-
started.
1.8004.59
0
470
SD T-ECU
SD alarm configuration; tem-
perature sensor for ECU de-
fective; short circuit or wire
break
Check sensor and
wiring, replace as
necessary. Fault is
cleared when en-
gine restarted.
1.8004.58
7
471
SD Suction Throttle
SD alarm configuration; suc-
tion throttle control defec-
tive; short circuit or wire
break
Check sensor and
wiring, replace as
necessary. Fault is
cleared when en-
gine restarted.
1.8004.59
2
472
AL Stop SD
Alarm configuration; engine
shutdown, since all shut-
down channels have “sensor
faulty”.
1. Check wiring.
2. Contact Service.
2.8006.59
3
473
AL Wiring PWM_CM2
Alarm configuration; Wire
break or short circuit on
channel PWM_CM2.
1. Check wiring.
2. Contact Service.
1.8004.59
3
474
AL Wiring FO
Alarm configuration; Wire
break or short circuit on
channel FO.
1. Check wiring.
2. Contact Service.
2.8006.65
5
475
AL CR Engine Shutdown
Trigger
Alarm configuration; activat-
ed when crash recorder trig-
gered by an engine shutdown
Determine and rec-
tify cause of trig-
gering/engine shut-
down.
1.8010.00
9
476
AL Crash Rec. Init. Error
Alarm configuration; crash
recorder initialization fault.
Check setting using
DiaSys.
1.8010.00
7
478
AL Comb. Alarm Yel
(Plant)
Alarm configuration; YELLOW
combined alarm from plant.
Check other fault
messages.
2.8006.00
1
58 | Troubleshooting | MS150026/02E 2013-11