1.4540.029 – Battery Volt Low Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Supply voltage has reached
minimum limit value.
1. Check supply voltage.
2. Check cabling.
1.4540.030 – FGT Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
u
Restart TecJet.
1.4540.031 – Delta P Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
u
Restart TecJet.
1.4540.032 – FGP Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Configured limit value was not
attained.
u
Check position direction of TecJet.
1.4540.033 – Battery Volt High Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Supply voltage has reached
maximum limit value.
1. Check supply voltage.
2. Check cabling.
1.4540.034 – FGT High Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
u
Restart TecJet.
1.4540.035 – Delta P High Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
u
Restart TecJet.
MS150098/02E 2016-11
| Troubleshooting | 75
TIM-ID: 0000027854 - 001