189 – AL CAN2 Error Passive
Yellow alarm.
Associated parameter 2.0500.689
Cause
Corrective action
CAN controller 2 has indicated a
warning. Some reasons are, for
example, no corresponding node,
minor malfunctions or temporary
bus overload.
u
Check operation of bus users and cabling.
190 – AL EMU Parameter Not Supported
Red alarm.
Associated parameter 2.0500.690
Cause
Corrective action
EMU parameters are not
supported.
u
Contact Service. (Configuration fault)
201 – SD T-Coolant
Red alarm. Engine shutdown.
Associated parameter 1.8004.570
Cause
Corrective action
Coolant temperature sensor at
engine outlet defective, short
circuit or wire break.
u
Check sensor and cabling (B6.1), replace if necessary. Fault is
rectified following engine restart.
204 – SD Level Lube Oil
Red alarm. Engine shutdown.
Associated parameter 1.8004.602
Cause
Corrective action
Engine oil level sensor defective,
short circuit or wire break.
u
Check sensor and cabling (B24), replace as necessary. Fault is
rectified following engine restart.
206 – SD T-Exhaust A
Yellow alarm.
Associated parameter 1.8004.576
Cause
Corrective action
Exhaust temperature sensor on A
side defective, short circuit or
wire break.
u
Check sensor and cabling (B4.21), replace if necessary. Fault is
rectified following engine restart.
102 | Troubleshooting | MS150098/02E 2016-11
TIM-ID: 0000027858 - 001