6.21.3 Start interlock limit switch – Check
Preconditions
☑ Engine is stopped and starting disabled.
Note:
Being in OFF-position, the limit switch initiates start interlock, i.e. the engine cannot be started.
Start interlock limit switch – Check
1.
Check if switch housing (1) and cover plate
(3) are mounted and the switch (2) is in ON-
position.
2.
If switch housing (1) and/or cover plate (3)
is/are not mounted:
• Secure cover plate (3) with screws.
• Then install switch housing (1) with
screws, ensuring that the switch (2) is
actuated by the cover plate (3).
3.
If switch housing (1) and cover plate (3) are
mounted, but switch (2) is in OFF-position:
• Make certain that the cover plate (3) at
the side of the switch (2) is not distorted.
• Loosen switch housing (1) and fit it with
screws in a position providing that the
switch (2) is ON.
• If this is not feasible, contact Service.