2.6.2 8V 2000 M40A engine data: separate heat exchanger, reference conditions:
25 °C intake air temperature
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated without changes (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model
8V 2000
M40A
Application group
3B
Intake air temperature
°C
25
Raw water inlet temperature
°C
25
Barometric pressure
mbar
1000
Site altitude above sea level
m
100
POWER-RELATED DATA (power ratings are net brake power to ISO 3046)
Number of cylinders
8
Engine rated speed
A rpm
1500
Continuous power ISO 3046 (10% overload capability) (design power DIN
6280, ISO 8528)
A kW
385
GENERAL CONDITIONS (for maximum power)
Number of cylinders
8
Intake air depression (new filter)
A mbar
15
Intake air depression, max.
L mbar
50
MODEL-RELATED DATA (basic design)
Number of cylinders
8
Cylinder configuration: V angle
Degrees
90
Bore
mm
130
Stroke
mm
150
Cylinder displacement
liter
1.99
Total displacement
liter
15.92
Number of inlet valves per cylinder
2
Number of exhaust valves per cylinder
2
34 | Product Summary | MS150031/03E 2011-10
TIM-ID: 0000010986 - 001
Содержание 12 V 2000 M40A
Страница 4: ......
Страница 20: ...Fuel system covers 20 Product Summary MS150031 03E 2011 10 TIM ID 0000002178 003 ...
Страница 21: ...MS150031 03E 2011 10 Product Summary 21 TIM ID 0000002178 003 ...
Страница 22: ...Lube oil system covers 22 Product Summary MS150031 03E 2011 10 TIM ID 0000002178 003 ...
Страница 23: ...MS150031 03E 2011 10 Product Summary 23 TIM ID 0000002178 003 ...