6.22.3 LOP – Test procedures
Preconditions
☑ Engine is stopped and starting disabled.
Preparatory steps
1.
Connect battery in accordance with battery
manufacturer's instructions.
2.
Switch master power switch to ON.
3.
Switch on engine management system
ECS-5.
Result:
• LOCAL OPERATION pushbutton (1) is il‐
luminated brightly (local control mode is
active);.
Switching between Local and Remote mode (automatic on-board network)
1.
Press LOCAL OPERATION pushbutton (1).
Result:
• LOCAL OPERATION pushbutton (1) flashes: Setting does not correspond with feedback signal from
Engine Control Unit.
• LOCAL OPERATION pushbutton (1) is illuminated at basic brightness: Remote mode active.
2.
Press LOCAL OPERATION pushbutton (1) again.
Result:
LOCAL OPERATION pushbutton (1) is illuminated brightly (Local mode is active);.
MS150031/03E 2011-10 | Task Description | 183
TIM-ID: 0000008872 - 003
Содержание 12 V 2000 M40A
Страница 4: ......
Страница 20: ...Fuel system covers 20 Product Summary MS150031 03E 2011 10 TIM ID 0000002178 003 ...
Страница 21: ...MS150031 03E 2011 10 Product Summary 21 TIM ID 0000002178 003 ...
Страница 22: ...Lube oil system covers 22 Product Summary MS150031 03E 2011 10 TIM ID 0000002178 003 ...
Страница 23: ...MS150031 03E 2011 10 Product Summary 23 TIM ID 0000002178 003 ...