Diagram for 10 V engines (two
crankshaft positions)
1 Cylinder A1 is in firing TDC
2 Cylinder A1 is in overlap TDC
I Inlet valve
X Exhaust valve
Diagram for 12 V engines (two
crankshaft positions)
1 Cylinder A1 is in firing TDC
2 Cylinder A1 is in overlap TDC
I Inlet valve
X Exhaust valve
Checking valve clearance at two crankshaft positions
1.
Check TDC position of piston in cylinder A1:
• If the rocker arms are unloaded on cylinder A1, the piston is in firing TDC.
• If the rocker arms are under load on cylinder A1, the piston is in overlap TDC.
2.
Check valve clearance with cold engine:
• Inlet = 0.3 +/- 0.05 mm;
• Exhaust = 0.6 +/- 0.05 mm.
3.
Check all valve clearances in two crankshaft positions (firing TDC and overlap TDC of cylinder A1) as
per diagram.
4.
Use feeler gauge to determine the distance between valve bridge and rocker arm.
5.
If the deviation from the reference value exceeds 0.1 mm, adjust valve clearance.
96 | Task Description |
MS150076/05E 2014-02
T
I
M
-
I
D
:
0
0
0
0
0
0
0
8
9
9
-
0
0
8