7.10 Coolant Circuit, General, High-Temperature Circuit
7.10.1
Engine coolant – Level check
Preconditions
☑
Engine is stopped and starting disabled.
☑
MTU Fluids and Lubricants Specifications (A001063/..) are available.
WARNING
Coolant is hot and under pressure.
Risk of injury and scalding!
• Let the engine cool down.
• Wear protective clothing, gloves, and goggles / safety mask.
Coolant-level check at filler
neck:
1.
Turn breather valve on coolant expansion
tank counterclockwise to the first stop and
allow pressure to escape.
2.
Continue to turn breather valve counter-
clockwise and remove.
3.
Check coolant level (coolant must be visi-
ble at the lower edge of the cast-in eye or
at the marking plate).
4.
Top up with treated coolant as necessary
(→ Page 112).
5.
Check breather valve (visual inspection)
and clean if necessary.
6.
Place breather valve on filler neck and
close.
Coolant-level check by means of level sensor:
1.
Switch on engine control system and check readings on the display.
2.
Top up with treated coolant as necessary (→ Page 112).