4 Operation
4.1 Putting the engine into operation after extended out-of-service
periods (>3 months)
Preconditions
☑
Engine is stopped and starting disabled.
☑
MTU Preservation and Represervation Specifications (A001070/..) are available.
Putting the PowerPack into operation after extended out-of-service-periods (>3
months)
Item
Action
Engine
Depreserve (→ MTU Preservation and Represervation Specifications
A001070/..).
Lube oil system
Check engine oil level (→ Page 106).
Fuel system
Vent (→ Page 99).
Engine coolant circuit
If engine is out of service for more than one year, change engine coolant
(→ Page 110).
Engine coolant circuit
Check engine coolant level (→ Page 109).
Engine governor
Check plug connections (→ Page 123).
Monitoring system
Carry out lamp test (see manufacturer's documentation).
Engine/generator control
system
Switch ON;
select operating mode, e.g. MANUAL, AUTOMATIC OPERATION.