background image

R-Series

Brief Instructions

Temposonics

®

Magnetostrictive Linear Position Sensors

Содержание Temposonics R-Series

Страница 1: ...R Series Brief Instructions Temposonics Magnetostrictive Linear Position Sensors ...

Страница 2: ...y 5 2 6 Return 5 2 7 Maintenance removal 5 3 Identification 6 3 1 Temposonics RP 6 3 2 Temposonics RH 6 3 3 Temposonics RD4 7 3 4 Temposonics RT4 7 3 5 Temposonics RF 7 4 Installation mounting 8 4 1 Magnet installation 8 4 2 Mounting dimensions of R Series 9 4 3 Multi position measurement distances 11 5 Electrical connections 12 5 1 Analog 13 5 2 SSI 13 5 3 Profibus 14 5 4 CANbus 15 5 5 DeviceNet ...

Страница 3: ...e of damage to the described product or connected devic es In this documentation safety information and warnings to avoid danger that might affect the life and health of operating or service personnel or cause material damage are highlight ed by the pictogram defined below Symbol Meaning NOTICE This symbol is used to point to situations that may lead to material damage but not to personal injury 1...

Страница 4: ...r connection The sensor does not work properly or can be destroyed Operate the sensor out of the operating temperature range No signal output The sensor can be damaged Power supply is out of the defined range Signal output is wrong no signal output the sensor can be damaged Position measurement is influenced by an external magnetic field Signal output is wrong Cables are damaged Short circuit The ...

Страница 5: ...e that nobody s safety is jeopardized by starting machines 2 4 Safety instructions for use in explosion hazardous areas The sensors are not suitable for operation in explosion hazardous areas 2 5 Warranty MTS Sensors grants a warranty 2 period for the Temposonics position sensors and supplied accessories relating to materi al defects and faults that occur despite correct use in accor dance with th...

Страница 6: ...ge Sensor electronics housing Available outputs Analog SSI Profibus CANbus DeviceNet EtherCAT EtherNet IP Powerlink Profinet Available outputs Analog SSI Profibus CANbus DeviceNet EtherCAT EtherNet IP Powerlink Profinet Approvals and certificates You will find approvals and certificates in the sensor specific operation manuals Nameplate e g RH SSI RHM0425MD701S1G2100 0 01 mm 25 Bit gray Grd 2797 1...

Страница 7: ...et Connector or cable outlet Ground lug Sensor electronics housing Flexible rod with sensor element Optional threaded flange Position magnet Ring or U magnet Connector or cable outlet Ground lug Pressure proof rod with sensor element Threaded flange Sensor electronics housing 3 4 Temposonics RT4 3 5 Temposonics RF Available outputs SSI Available outputs Analog SSI Profibus CANbus DeviceNet EtherCA...

Страница 8: ...care to mount the primary sensor axis in parallel to the magnet path in order to avoid damage to the carriage magnet and sensor rod 4 Installation mounting Controlling design dimensions are in millimeters and measurements in are in inches Magnet mounting with magnetic material When using magnetic material the dimensions in the drawing beneath must be observed If the position magnet is set fur ther...

Страница 9: ...4 End position 63 5 2 5 RP with block magnet RD4 M T G with ring magnet U magnet Reference edge of mounting Sensor electronics housing Stroke length 5000 mm 196 9 in End position 68 5 73 5 2 7 2 9 Start position 25 5 1 Reference edge of mounting Start position 51 2 01 End position 63 5 66 2 5 2 6 Stroke length 5000 mm 196 9 in RH with ring magnet U magnet RD4 C D with ring magnet U magnet Sensor e...

Страница 10: ...sition 51 2 01 End position See table RF M S with block magnet Sensor electronics housing Reference edge of mounting Start position 48 5 1 91 End position See table NOTICE The sensor can be operated in any orientation Controlling design dimensions are in millimeters and measurements in are in inches Stroke length RF End position of ring magnet U Magnet Tolerance of total length Up to 7620 mm 300 0...

Страница 11: ...CE Use magnets of the same type for multi position measurement e g 2 U magnets part no 251416 2 Multi position measurements are output signal dependent possible The acquisition of up to 20 positions or 5 positions and their velocities Please note that the stroke length influences the maximum number of magnets Controlling design dimensions are in millimeters and measurements in are in inches Manual...

Страница 12: ...ith potential differences between machine and electronics earth connections no compensating currents are allowed to flow across the cable shielding Recommendation Install potential compensating leads with large cross section or use cables with separate double shielding and connect only one end of the shield Use only stabilized power supplies in compliance with the specified connecting values LED s...

Страница 13: ...N 24 VDC 15 20 WH DC Ground 0 V order dependent NOTICE Mind the hazard of short circuits When using only output 1 insulation of the yellow and green cores output 2 is indispensable Recommendation Provide terminals for output 2 in the control cabinet because the leads are eventually required in case of sensor programming 5 2 SSI D70 Signal power supply M16 male connector Color Function 1 4 2 6 3 5 ...

Страница 14: ...male connector Pin Function 2 4 1 3 View on sensor 1 24 VDC 15 20 2 Not connected 3 DC Ground 0 V 4 Not connected D63 Signal power supply M16 male connector Pin Function 1 2 3 6 5 4 View on sensor 1 RxD TxD N bus 2 RxD TxD P bus 3 Not connected 4 Not connected 5 24 VDC 15 20 6 DC Ground 0 V M16 female connector Pin Function 5 4 3 6 1 2 View on sensor 1 RxD TxD N bus 2 RxD TxD P bus 3 Data GND term...

Страница 15: ...ly M12 male connector A coded Pin Function 1 2 3 4 5 View on sensor 1 Shield 2 24 VDC 15 20 3 DC Ground 0 V 4 CAN_H 5 CAN_L M12 female connector A coded Pin Function 1 2 3 4 5 View on sensor 1 Shield 2 24 VDC 15 20 3 DC Ground 0 V 4 CAN_H 5 CAN_L D60 Signal power supply M16 male connector Pin Function 1 2 3 6 5 4 View on sensor 1 CAN_L 2 CAN_H 3 Not connected 4 Not connected 5 24 VDC 15 20 6 DC Gr...

Страница 16: ...aster Modul status Green Red Information ON OFF Normal function OFF ON Magnet not detected 5 6 EtherCAT D56 Signal M12 female connector D coded Pin Function 2 3 4 5 1 View on sensor 1 Tx 2 Rx 3 Tx 4 Rx 5 Not connected M12 female connector D coded Pin Function 2 3 4 5 1 View on sensor 1 Tx 2 Rx 3 Tx 4 Rx 5 Not connected Power supply M8 male connector Pin Function 2 4 1 3 View on sensor 1 24 VDC 15 ...

Страница 17: ... be independent of each other and floating not grounded under normal operation Ethernet IP LED status Network status Green Red Information ON OFF Connection established Flashing OFF No connection OFF ON Unrecoverable error OFF Flashing Recoverable error Port 1 In Green Red Information ON OFF LINK activity on port 1 Flickers OFF Data transfer on port 1 OFF ON No magnet wrong quantity of magnets Port...

Страница 18: ...N Missing magnet Port 2 Green Red Information ON OFF LINK activity on port 2 Flashing OFF Data activity on port 2 Bus error Green Red Information OFF ON Fault detected 5 9 Profinet D58 Signal M12 female connector D coded Pin Function 2 3 4 5 1 View on sensor 1 Tx 2 Rx 3 Tx 4 Rx 5 Not connected M12 female connector D coded Pin Function 2 3 4 5 1 View on sensor 1 Tx 2 Rx 3 Tx 4 Rx 5 Not connected Po...

Страница 19: ...Temposonics R Series Brief Instructions I 19 I Notes ...

Страница 20: ...com MTS Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Corporation within the United States These trademarks may be protected in other countries All other trademarks are the property of their respective owners Copyright 2018 MTS Systems Corporation No license of any intellectual...