Temposonics
®
R-Series
Brief Instructions
I
18
I
5.8 Powerlink
D56
Signal
M12 female connector
(D-coded)
Pin
Function
2
3
4
5
1
View on sensor
1
Tx (+)
2
Rx (+)
3
Tx (−)
4
Rx (−)
5
Not connected
M12 female connector
(D-coded)
Pin
Function
2
3
4
5
1
View on sensor
1
Tx (+)
2
Rx (+)
3
Tx (−)
4
Rx (−)
5
Not connected
Power supply
M8 male connector
Pin
Function
2
4
1
3
View on sensor
1
+24 VDC (−15 / +20 %)
2
Not connected
3
DC Ground (0 V)
4
Not connected
Powerlink LED status
Bus status
Green
Red
Information
ON
OFF
Connection established
Port 1
Green
Red
Information
ON
OFF
LINK activity on port 1
Flashing
OFF
Data activity on port 1
OFF
ON
Missing magnet
Port 2
Green
Red
Information
ON
OFF
LINK activity on port 2
Flashing
OFF
Data activity on port 2
Bus error
Green
Red
Information
OFF
ON
Fault detected
5.9 Profinet
D58
Signal
M12 female connector
(D-coded)
Pin
Function
2
3
4
5
1
View on sensor
1
Tx (+)
2
Rx (+)
3
Tx (−)
4
Rx (−)
5
Not connected
M12 female connector
(D-coded)
Pin
Function
2
3
4
5
1
View on sensor
1
Tx (+)
2
Rx (+)
3
Tx (−)
4
Rx (−)
5
Not connected
Power supply
M12 male connector
Pin
Function
1
2
4
3
View on sensor
1
+24 VDC (−15 / +20 %)
2
Do not connect!*
3
DC Ground (0 V)
4
Do not connect!*
* As a connection to this pin may influence
the correct startup of sensor.
Profi net LED status
Green
Red
Information
ON
OFF
Normal function
ON
ON
No connection to master
ON
Flashing Parameterization failed
OFF
ON
Warning! (illegal supply voltage /
wrong quantity of magnets)