Temposonics
®
R-Series
Brief Instructions
I
9
I
RP with magnet slider “S” / “N” / “V” / “G”
RH with block magnet
Sensor electronics housing
Reference edge of mounting
Start position
12 (0.47)
End position
82 / 87* (3.23 / 3.43*)
* Stroke length > 5000 mm (196.9 in.)
Sensor electronics housing
Reference edge of mounting
Start position
48.5 (1.91)
End position
66 / 68.5* (2.6 / 2.7*)
* Stroke length > 5000 mm (196.9 in.)
RP with U-magnet
RD4-S with ring magnet / U-magnet
Reference edge of mounting
Sensor electronics housing
Start position
28 (1.1)
End position
66 / 71* (2.6 / 2.8*)
* Stroke length > 5000 mm (196.9 in.)
Reference edge of mounting
Start position
21.4 (0.84)
End position
63.5 (2.5)
RP with block magnet
RD4-M / -T / -G with ring magnet / U-magnet
Reference edge of mounting
Sensor electronics housing
* Stroke length > 5000 mm (196.9 in.)
End position
68.5 / 73.5* (2.7 / 2.9*)
Start position
25.5 (1)
Reference edge of mounting
Start position
51 (2.01)
End position
63.5 / 66* (2.5 / 2.6*)
* Stroke length > 5000 mm (196.9 in.)
RH with ring magnet / U-magnet
RD4-C / -D with ring magnet / U-magnet
Sensor electronics housing
Reference edge of mounting
Start position
51 (2.01)
End position
63.5 / 66* (2.5 / 2.6*)
* Stroke length > 5000 mm (196.9 in.)
End position
63,5 / 66*
Reference edge of mounting
Start position
51 (2.01)
* Stroke length > 5000 mm (196.9 in.)
4.2 Mounting dimensions of R-Series
Controlling design dimensions are in millimeters and
measurements in ( ) are in inches