5. Cylinder handling after sensor installation
5.1 Washing and drying cylinders with installed sensors
Frequently, hydraulic cylinders are washed or degreased before painting. For this purpose, various chemical and/or thermal methods are used,
whereby cleaning agents are sprayed onto the components under high pressure up to 50 bar. During this procedure, the following measures relat-
ing to polyurethane (PUR) connecting cables and plug-in connections must be taken.
5.1.1 Sensors with Temposonics
®
M12 connector system
• When washing at low pressures up to approx. 5 bar, the plastic cap supplied with sensor and connector system is sufficient to
protect the M12 connector system (MTS material number GZ0605).
• When washing at higher pressures, an M12x1 metal protective device should be used to protect the connector system against
the effect of chemicals.
• The actual MTS connector system won‘t be damaged due to its high protection class, however, mating plugs which are con
-
nected subsequently might corrode due to the effect of chemicals.
• If temperatures higher than 105° C are used for drying after washing, the connector systems should not be exposed to this
temperature during more than about 5 minutes.
5.1.2 Sensors with connecting cable
• Protect the connecting cables using suitable enclosures (e.g. bags) against the effect of moisture, high pressures and tempera
-
tures.
• Normally, cable entry glands meet the requirements of IP 67, however, they are not pressure-tight. For this reason, they must
be protected against moisture as well, in order to prevent moisture from accumulating in the connecting compartment of the
cylinder.
• MTS connecting cables are made of PUR and relatively resistant against a large variety of chemicals and oils. However, excep
-
tions are e.g. carbon tetrachloride, trichloroethylene, perchloroethylene, which can be ingredients of fat solvents and cleaning
agents.
• Therefore, make sure that cables are protected adequately, if cleaning agents that can attack PUR are used.
• If temperatures higher than 105° C are used for drying after washing, the connecting cables shouldn‘t be exposed to this tem
-
perature during more than 5 minutes.
5.1.3 Sensors provided with third-party connectors
• If third-party connectors are used, a sealed screw cap must be fitted when washing, since third-party connectors normally have
only protection class IP67.
• Moreover, check if the housing of the third-party connector is sufficiently tight to resist high pressures when washing. If neces
-
sary, measures for protection of the housing should be taken.
• These connectors must be protected against the ingress of moisture as well to prevent moisture from accumulating in the con
-
necting compartment of the cylinder.
• If temperatures higher than 105˚C are used for drying after washing, third-party connectors shouldn‘t be exposed to this tem
-
perature during more than 5 minutes either.
IP69 K
IP67
IP67