MTS 793 Controller Hardware
FlexTest GT Controller Connections
159
J52 Box Out
The J52 Box Out connector provides an interface for connecting
multiple MTS controller boxes together to allow sharing of station
interlock status and a master synchronization clock.
Last controller jumper
The last controller box in a chain must have a jumper plug (MTS PN
100-079-126) on its
J52 Box Out
connector. This jumper allows the
return of the composite station interlock signal for all controllers in the
chain to monitor.
Note
If there is only one controller, a jumper is still required on its
Box
Out
connector.
Cable specification
Use MTS cable PN 056-534-1xx.
+clk in
/intlk out 2
/intlk out 1
/intlk out 3
/intlk out 4
test
-clk out
/intlk return in 1
/intlk return in 2
/intlk return in 3
/intlk return in 4
signal return
signal return
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
J52 Box Out
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com