Series 1750 Bedding Dispensers
61301604063
3–5
EMERGENCIES
Emergency Stop
In an emergency, stop the bedding dispenser immediately.
Use either procedure below.
EMERGENCY STOP
1.
Press EMERGENCY STOP.
•
The bedding dispenser ceases operation.
•
The conveyor of the tunnel washer stops.
•
An alarm sounds at the load end of the tunnel washer.
2.
To restart the bedding dispenser:
a.
Pull out EMERGENCY STOP to reset the switch.
b.
Press START.
— OR —
POWER
1.
Turn OFF the POWER switch.
•
The bedding dispenser ceases operation.
2.
To restart the bedding dispenser:
a.
Turn ON the POWER Switch.
b.
Press START.
Emergency Power Shutoff
In an emergency, it may be necessary to remove electrical power from the
bedding dispenser. All operators should know the location of the mains
disconnect circuit breaker at the bedding dispenser site.
The POWER switch turns OFF the controls only; it does not remove all
power from the bedding dispenser.
TURNING OFF ELECTRICAL POWER
Turn OFF power to the bedding dispenser at the mains disconnect circuit
breaker (see Figure 1–2. EXTERIOR COMPONENTS (unload end)).
Содержание 1750 Series
Страница 1: ...SERIES 1750 AUTOMATIC TYPE TUNNEL BEDDING DISPENSERS USER MANUAL 61301604063 Rev A...
Страница 2: ......
Страница 8: ...vi Conveyor Stop 7 3 DESCRIPTION 7 3 USER CONTROLS 7 3 MAINTENANCE REQUIRED 7 3 Index...
Страница 18: ...General Description 1 8...
Страница 28: ...Operating Instructions 3 6...
Страница 30: ...Maintenance 4 2 Figure 4 1 GREASE FITTINGS GREASE HERE GREASE HERE Load End Unload End A04063 F...
Страница 32: ...Maintenance 4 4...
Страница 44: ...Options 7 4...
Страница 48: ...I 4...
Страница 49: ......