Installation and Operational Manual
•
Boutique Collection
•
SculptureStone® Tubs
9 / mtibaths.com
Blower
(remotely located)
Connect to a
dedicated 15amp GFCI.
Blower: 110V 9.5 amps
Check Valve - must be mounted
horizontally (as shown) and at
least 2” above rim of tub.
Rigid 1”
schedule
40 PVC
Air hose - leading to
bottom of tub
Ethernet Cable
Connects from blower to
remote control receiver.
Water Sensor Wires
Wires lead from sensors
mounted on either side of tub
drain and connect to blower.
Allows activation of purge cycle
after tub has drained.
Remote Control Receiver
Connection to blower required
for remote control to work.
Ethernet Cable
Connects from remote
control receiver to keypad.
Keypad
Can be mounted convenient to
bather, or simply left unattached if
only the remote control is desired.
Do not use.
13
13””
Blower Dimensions:
13”l x 8”w x 9”h
99””
Installation Instructions – Airbath
Illustration A
Illustration B
The following illustrations are referenced in the instructions on page 8.