background image

P31 SERIES 

Section P31

 Page 501

Dated 

October 2010

97-5006-01-588

Pump Manual

HORIZONTAL CLOSE COUPLED

ADJUSTABLE  PERFORMANCE

INTEGRAL RELIEF VALVE OPTION

Содержание P31 Series

Страница 1: ...P31 SERIES Section P31 Page 501 Dated October 2010 97 5006 01 588 Pump Manual HORIZONTAL CLOSE COUPLED ADJUSTABLE PERFORMANCE INTEGRAL RELIEF VALVE OPTION...

Страница 2: ...the shaft Apply ing torque to the motor fan blades is not recommended If the impeller does not break loose immediately fill the pump with a process compatible fluid and try again in a few hours If thi...

Страница 3: ...in feet of pumped liquid The NPSH is actually a measurement of the amount of energy available in the pumped liquid to produce the required absolute entrance velocity in the pump If a pump requires mo...

Страница 4: ...l the components required for servic ing plus shaft sleeve and drive keys should be obtained A factory re build should be considered whenever your disassembly indicates rebuilding is necessary as this...

Страница 5: ...foundation until it has been properly aligned The foundation must be a perma nent rigid installation of concrete or other material of sufficient mass to absorb all normal vibrations Locate the founda...

Страница 6: ...ant to be aware of and follow the appropriate local and na tional electrical codes Do not make wiring alterations that can affect motor rotation without reconfirming correct rotation Select starters a...

Страница 7: ...uction lines are desirable to minimize priming time Usingtheself primingequipment itis only necessary to 1 Open the plugs in both the inlet and discharge chambers 2 Pour fluid in one until both are fu...

Страница 8: ...able consideration should be given to switching to a sealless leak free design Most MTH pumps are available in a sealless canned motor design See the SP31 4B Flushing Lines External Flushing lines are...

Страница 9: ...x 6 long 8 Thin blade screwdriver 9 Cealube G P 80 or glycol base lubricant compatible with the pro cess fluid and O ring elastomers DO NOT use petroleum prod ucts To disassemble the pump Refer to Fig...

Страница 10: ...rances between the casing and impeller probably exceed the maximum allow able The P31 features an adjustable casing that may allow return to like new performance See Section 5D for more information If...

Страница 11: ...ng careful not to damage the seat or the rotating element 4 Compress and hold the seal spring slightly below the snap ring groove and install the snap ring 4 Make sure the snap ring is locked firmly i...

Страница 12: ...al attention should be given to the seal area where the motor shaft enters the motor bracket 6 Under pressure the impeller will find its hydraulic balance 7 Using an amprobe or similar de vice check f...

Страница 13: ...onents 6 Air pockets in the suction piping Operating the system at maximum flow conditions will usually clear the lines Evacuate the system with a vacuum pump if necessary 7 Suction lines strainer or...

Страница 14: ...clear ances rusty Follow installation instructions for loosening the pump Foreign material in pump Flush out Disassemble if flushing is not successful 3 Pump leaks Seal or O rings are usually the pro...

Страница 15: ...ump was purchased or supplied Complete details on what is wrong with the pump must be provided along with information on the system in which it is installed Refer to the MTH Pumps Limited Warranty sta...

Страница 16: ...marked with the Return Goods Authorization RGA number provided by MTH and shipped freight prepaid and allowed F O B the MTH factory at Plano Illinois USA MTH may in its sole discretion deny any warra...

Отзывы: