Marine Cleaner for ten minutes, stir several times
and check whether the float acts smoothly and
freely. Repeat the above activities, if required.
The circuit
breaker is
mounted too
low
If the pump sucks air and the circuit breaker has
not been positioned at OFF, the circuit breaker
may be mounted too low with respect to the
pump. Mount it at a level at least 1/4 higher than
the pump base.
Overheated
cables,
melted
insulation
Contaminated
rotor and
improperly
rated fuse.
Ensure that the rotor is clean and may rotate
freely. Reduce fuse to proper rating. Replace
damaged cables and/or switch.
Regular,
recurring
fuse blowing
Fuse rating or
locked rotor
Ensure that the fuse is properly rated. Check if
the rotor is locked, e.g. with a fishing line.
Содержание MSW-M-BP-2000
Страница 15: ......