background image

User Manual - PolyGard

®

2 / µGard

®

Sensors for Toxic Gases 

 

 
 

Page  12    

   

 

 

PolyGard

 / µGard

® 

are registered trademarks of MSR   

 

 

 

Made in Germany   

 

   GA_SC2_MC2_Tox_D_0820 

 
Phone +49 8531 9004-0 

Fax: +49 8531 9004-54 

  

 

 

 

      Specification subject to change without notice 

MSR-Electronic GmbH, Buergermeister-Schoenbauer-Str. 13, D 94060 Pocking   

 

 

 

 

 

   www.msr-electronic.de 

9.3

 

Sensor Element 

SPECIFICATIONS - Sensor Cartridge (SC2/MC2) / Sensor element 
 

Gas 

ty

pe

 

O

rde

ri

ng

 N

o.

 

M

easuri

ng

 r

ang

A

cc

ura

cy

 

D

isp

lay

 r

eso

luti

on

 

R

ep

eat

abi

lity

 

t90 

ti

me

 

Ze

ro

-p

oi

nt 

va

ri

at

io

D

ri

ft 

in

 

ai

Temp

er

atu

re 

ra

ng

H

umidit

ra

ng

(no

n-

co

nde

ns

ing

Lif

time

 

in 

air

 

R

el

at

ive

 Gas 

de

nsi

ty

2

 

C

ali

bra

ti

on

  

in

te

rv

al

1

 

Zero

 

Gai

n

 

 

SC2-/MC2-  ppm 

± % 
sig. 

ppm 

<±  % 
sig. 

≤ sec.

  ±ppm  < % signal/ 

month 

°C  

% r. F. 


months 

Air = 1  Month 

NH

3

 

E1125-AX  0

100  5 

0.1 

10 

75 

-30 / +50  15

90  24 

0.60  12 

NH

3

 

E1125-BX  0

300  3 

0.1 

10 

75 

-30 / +50  15

90  24 

0.60  12 

NH

3

 

E1125-CX  0

500  3   0.1 

10 

75 

-30 / +50  15

90  24 

0.60  12 

NH

3

 

E1125-DX  0

1000  3   1 

10 

75 

10 

-30 / +50  15

90  24 

0.60  12 

NH

3

 

E1125-EX  0

5000  2 

10 

40 

100  1 

-30 / +50  15

90  24 

0.60  12 

Cl

2

 

E1193-CX  0

10 

n.d.  0.01 

40 

0.2 

-30 / +50  15

90  24 

2.48  6 

Cl

2

 

E1193-DX  0

20 

n.d.  0.01 

40 

0.2 

-30 / +50  15

90  24 

2.48  6 

HCl 

E1186-DX  0

20 

0.01 

60 

0.5 

-20 / +50  15

90  24 

1.27  6 

HCN 

E1183-BX  0

50 

0.01 

30 

-20 / +50  15

90  24 

0.93  6 

HCN 

E1183-CX  0

100  5 

0.1 

30 

-20 / +50  15

90  24 

0.93  6 

ETO 

E1199-AX  0

10 

n.d.  0.01 

150  1 

+10 / +30  15

90  24 

1.56  12 

C

2

H

4

 

E1189-CX  0

200  n.d.  0.1 

120  5 

-30 / +50  15

90  24 

0.97  6 

CH

2

E1185-BX  0

10 

n.d.  0.01 

60 

0.2 

-30 / +50  15

90  36 

1.04  6 

CO 

E1110-CX  0

150  2   0.1 

10 

0.4 

0.4  -20 / +50  10

95  72 

0.97  12 

CO 

E1110-EX  0

250  2   0.1 

10 

0.4 

0.4  -20 / +50  10

95  72 

0.97  12 

CO 

E1110-FX  0

300  2   0.1 

10 

0.4 

0.4  -20 / +50  10

95  72 

0.97  12 

CO 

E1110-HX  0

500  2 

0.1 

10 

0.4 

0.4  -20 / +50  10

95  72 

0.97  12 

O

3

 

E1190-AX  0

n.d.  0.001  5 

60 

0.1 

-30 / +50  15

90  24 

1.66  6 

O

3

 

E1190-BX  0

10 

n.d.  0.01 

60 

0.2 

-30 / +50  15

90  24 

1.66  6 

SO

2

 

E1196-BX  0

20 

3   0.01 

30 

0.2 

-20 / +50  15

90  24 

2.73  6 

H

2

E1197-AX  0

50 

3   0.01 

30 

-10 / +50  15

90  24 

1.19  12 

H

2

E1197-BX  0

100  3   0.1 

40 

-10 / +50  15

90  24 

1.19  12 

H

2

E1197-CX  0

200  3 

0.1 

40 

-10 / +50  15

90  24 

1.19  12 

H

2

E1197-DX  0

500  3 

0.1 

40 

-10 / +50  15

90  24 

1.19  12 

H

2

E1197-EX  0

1500  3 

60 

15 

n.d.  n.d.  -10 / +50  15

90  24 

1.19  12 

NO

2

 

E1130-AX  0

10 

5   0.01 

25 

0.2 

-30 / +50  15

90  24 

2.80  12 

NO

2

 

E1130-BX  0

20 

5   0.01 

25 

0.2 

-30 / +50  15

90  24 

2.80  12 

NO

2

 

E1130-CX  0

30 

5   0.01 

25 

0.2 

-30 / +50  15

90  24 

2.80  12 

NO

2

 

E1130-EX  0

100  5   0.1 

25 

-30 / +50  15

90  24 

2.80  12 

 

 

Vol % 

 

 

 

 

 

 

 

 

 

 

 

 

O

2

 

E1195-
A2/3 

0

25 

0.01 

n.d. 

15 

n.d. 

n.d.  0.4/

0.6 

-40 / +50  5

95 

24/36   1.11  6/6 

O

2

 

E1195-
A5/7 

0

25 

0.01 

n.d. 

15 

n.d. 

n.d.  0.4  -40 / +50  15

90  60/84  1.11  12/12 

 

1

 Manufacturer-recommended calibration interval for normal environmental conditions  

2

 The sensor must be installed at the correct height depending on the relative gas density (d): 

 

 

   

 

 

 

d < 0.95: Mount on the ceiling 

 

 

   

 

 

 

0.95 < d < 1.05: Mount at a height of 1.5

1.8 m above floor 

 

 

   

 

 

 

d > 1.05: Mount at a height of 0.3 m above floor 

 

   Exception NO

2

: Mounting height for NO

2

 sensors: 0.5 to 1.8 m above floor! 

Exceeding the measuring range limit will include a risk of damaging the sensor element.  

Содержание PolyGard 2

Страница 1: ...t to change without notice MSR Electronic GmbH Buergermeister Schoenbauer Str 13 D 94060 Pocking www msr electronic de PolyGard 2 Gard 2 Sensors for Toxic Gases Sensor Cartridge for Toxic Gases and Ox...

Страница 2: ...n SB2 MSB2 MSC2 WSB2 5 3 2 Terminal Connection MC2 5 4 Commissioning 5 4 1 Installation of Sensor Cartridge 5 4 2 Registration of the Sensor Cartridge 5 5 Calibration 6 5 1 Calibration Work 6 5 2 Exch...

Страница 3: ...C2 MSB2 and WSB2 devices 1 3 Special Mode See description of the SB2 MSC2 MSB2 and WSB2 devices 1 4 Sensor Element for Toxic Gases and Oxygen The sensor element is a sealed electro chemical cell with...

Страница 4: ...1186 1 27 Floor 0 2 0 3 m Hydrogen cyanide E1183 0 93 Ceiling 0 3 m Ethylene oxide E1199 1 56 Floor 0 2 0 3 m Ethylene E1189 0 97 1 5 1 8 m Formaldehyde E1185 1 04 1 5 1 8 m Carbon monoxide E1110 0 97...

Страница 5: ...stalled ex works Check Sensor Cartridge connector for correct engagement Calibrate if not already factory calibrated Within the first weeks after commissioning there may be a deviation in the sensor b...

Страница 6: ...libra tion interval in months1 Ammonia NH3 24 300 150 12 Chlorine Cl2 NO2 1 1 CL2 24 30 500 6 Hydrogen chloride HCL H2S 20 31 HCl 24 30 500 6 Hydrogen cyanide HCN H2S 15 25 HCN 24 30 500 6 Ethylene ox...

Страница 7: ...calibration has been successfully completed If you exit the menu without pressing Save the original gain data for the measured value calculation will continue to be used By limiting the gain factor ca...

Страница 8: ...epend on the sensor element and can be read from the table Calibration If there are different intervals always observe the shortest one Inspections and services must be documented The date for the nex...

Страница 9: ...ension at X4 16 28 V DC Pin 1 and 2 Polarity not correct at X4 Connect correctly Connector X4 not plugged in Check the plug Wire breakage Check the wiring Green LED doesn t flash PCB no address Check...

Страница 10: ...rent signal 50 k for voltage signal 4 20 mA or 2 10 V measuring range 3 2 4 mA or 1 6 2 V underrange 20 21 2 mA or 10 10 6 V overrange 2 mA or 1 V fault 21 8 mA or 10 9 V fault High SENSOR ELEMENT Gas...

Страница 11: ...1 F to 68 F for NH3 CO NO2 O2 Storage time 6 months Poisoning Electrochemical sensors are susceptible to poisoning by organic solvents and silicone vapours PHYSICAL Housing in plastic Polycarbonate Co...

Страница 12: ...1185 BX 0 10 n d 0 01 5 60 0 2 1 2 30 50 15 90 36 1 04 6 CO E1110 CX 0 150 2 0 1 5 10 4 0 4 0 4 20 50 10 95 72 0 97 12 CO E1110 EX 0 250 2 0 1 5 10 4 0 4 0 4 20 50 10 95 72 0 97 12 CO E1110 FX 0 300 2...

Страница 13: ...5000 0 10 12 10 30 20 0 20 0 1000 150 NH3 E1125 CX 10 0 100 0 100 0 200 0 5000 0 10 12 10 30 20 0 20 0 1000 150 NH3 E1125 DX 10 0 100 0 100 0 200 0 5000 0 10 12 10 30 20 0 20 0 1000 150 NH3 E1125 EX 1...

Страница 14: ...1 9004 0 Fax 49 8531 9004 54 Specification subject to change without notice MSR Electronic GmbH Buergermeister Schoenbauer Str 13 D 94060 Pocking www msr electronic de 10 Figures v Fig 1 Fig 3 PCB wit...

Страница 15: ...d 2 devices are installed in compliance with all national and local codes and OSHA requirements Installation should be implemented only by technicians familiar with proper installation techniques and...

Отзывы: