9.2

 

Sensor Cartridge (SC2) 

ELECTRICAL  

Power supply 

5 V DC from Sensor Board (e.g. SB2/MSB2), reverse polarity 
protected 

Power consumption:  

10 mA, max. (0.05 VA) 

Serial interface local bus 

1-wire / 19200 Baud 

SENSOR ELEMENT 

Gas type 

See Ordering Information 

Sensor element 

Electrochemical 

Pressure range 

Atmospheric ± 10 %  

Storage temperature range

1

 

0 °C to 20 °C (32°F to 68 °F) or  
5 °C to 20 °C (41°F to 68 °F) for NH

3

, CO, NO

2

, O

2

 

Storage time 

6 months 

Poisoning 

Electrochemical sensors are susceptible to poisoning by organic 
solvents and silicone vapours. 

PHYSICAL 

Housing in plastic 

Polycarbonate  

Combustion 

UL 94 V2 

Housing colour 

RAL 7032 (light grey) 

Dimensions: Housing type P 
 

Housing type L 

(D x H) 24 x 22 mm (0.94 x 0.87 in.) 
(D x H) 24 x 30 mm (0.94 x 1.18 in.) 

Weight 

Ca. 30 g (0.07 lb) 

Protection class 

IP65  

Mounting 

Screw mounting 

Connection type 

3-pin connector 

Cable length  

110 mm (4.33 in.) 

REGULATIONS 

Directives  

EMC Directives 2014/30/EU 
CE 
 
Conformity to:  
EN 378 
EN 45544-1 
EN 50104 (for O

2

EN 50545 
EN 50271 
EN 61010-1  
ANSI/UL 61010 1  
CAN/CSA-C22.2 No. 61010-1 

Warranty 

1 year on sensor (not if poisoned or overloaded),  
2 years on device 

 

1

 A higher storage temperature can have a negative effect on sensitivity and service life. 

We recommend recalibrating the devices if stocked for a longer period (>8 weeks)  

 

Содержание PolyGard 2

Страница 1: ...t to change without notice MSR Electronic GmbH Buergermeister Schoenbauer Str 13 D 94060 Pocking www msr electronic de PolyGard 2 Gard 2 Sensors for Toxic Gases Sensor Cartridge for Toxic Gases and Ox...

Страница 2: ...n SB2 MSB2 MSC2 WSB2 5 3 2 Terminal Connection MC2 5 4 Commissioning 5 4 1 Installation of Sensor Cartridge 5 4 2 Registration of the Sensor Cartridge 5 5 Calibration 6 5 1 Calibration Work 6 5 2 Exch...

Страница 3: ...C2 MSB2 and WSB2 devices 1 3 Special Mode See description of the SB2 MSC2 MSB2 and WSB2 devices 1 4 Sensor Element for Toxic Gases and Oxygen The sensor element is a sealed electro chemical cell with...

Страница 4: ...1186 1 27 Floor 0 2 0 3 m Hydrogen cyanide E1183 0 93 Ceiling 0 3 m Ethylene oxide E1199 1 56 Floor 0 2 0 3 m Ethylene E1189 0 97 1 5 1 8 m Formaldehyde E1185 1 04 1 5 1 8 m Carbon monoxide E1110 0 97...

Страница 5: ...stalled ex works Check Sensor Cartridge connector for correct engagement Calibrate if not already factory calibrated Within the first weeks after commissioning there may be a deviation in the sensor b...

Страница 6: ...libra tion interval in months1 Ammonia NH3 24 300 150 12 Chlorine Cl2 NO2 1 1 CL2 24 30 500 6 Hydrogen chloride HCL H2S 20 31 HCl 24 30 500 6 Hydrogen cyanide HCN H2S 15 25 HCN 24 30 500 6 Ethylene ox...

Страница 7: ...calibration has been successfully completed If you exit the menu without pressing Save the original gain data for the measured value calculation will continue to be used By limiting the gain factor ca...

Страница 8: ...epend on the sensor element and can be read from the table Calibration If there are different intervals always observe the shortest one Inspections and services must be documented The date for the nex...

Страница 9: ...ension at X4 16 28 V DC Pin 1 and 2 Polarity not correct at X4 Connect correctly Connector X4 not plugged in Check the plug Wire breakage Check the wiring Green LED doesn t flash PCB no address Check...

Страница 10: ...rent signal 50 k for voltage signal 4 20 mA or 2 10 V measuring range 3 2 4 mA or 1 6 2 V underrange 20 21 2 mA or 10 10 6 V overrange 2 mA or 1 V fault 21 8 mA or 10 9 V fault High SENSOR ELEMENT Gas...

Страница 11: ...1 F to 68 F for NH3 CO NO2 O2 Storage time 6 months Poisoning Electrochemical sensors are susceptible to poisoning by organic solvents and silicone vapours PHYSICAL Housing in plastic Polycarbonate Co...

Страница 12: ...1185 BX 0 10 n d 0 01 5 60 0 2 1 2 30 50 15 90 36 1 04 6 CO E1110 CX 0 150 2 0 1 5 10 4 0 4 0 4 20 50 10 95 72 0 97 12 CO E1110 EX 0 250 2 0 1 5 10 4 0 4 0 4 20 50 10 95 72 0 97 12 CO E1110 FX 0 300 2...

Страница 13: ...5000 0 10 12 10 30 20 0 20 0 1000 150 NH3 E1125 CX 10 0 100 0 100 0 200 0 5000 0 10 12 10 30 20 0 20 0 1000 150 NH3 E1125 DX 10 0 100 0 100 0 200 0 5000 0 10 12 10 30 20 0 20 0 1000 150 NH3 E1125 EX 1...

Страница 14: ...1 9004 0 Fax 49 8531 9004 54 Specification subject to change without notice MSR Electronic GmbH Buergermeister Schoenbauer Str 13 D 94060 Pocking www msr electronic de 10 Figures v Fig 1 Fig 3 PCB wit...

Страница 15: ...d 2 devices are installed in compliance with all national and local codes and OSHA requirements Installation should be implemented only by technicians familiar with proper installation techniques and...

Отзывы: