background image

1.4 Limited Warranty 

INTEC Controls | MSR-Electronic GmbH

 does not assume any liability in case of improper or 

incorrect use of the de-vice. The installer and operator are exclusively responsible for the design 
and use of the product. If the product is not used, maintained or repaired in accordance with the 
instructions for use, warranty and product liability claims as well as claims arising from any 
guarantees assumed by 

INTEC Controls | MSR-Electronic GmbH

 for the product will be forfeited. 

INTEC Controls | MSR-Electronic GmbH

 warrants PolyGard

®

2/PolyXeta

®

2 devices against defects in 

material or work-manship for a period of 2 years (1 year for sensors) from the date of shipment. 
Should a defect in material or workmanship occur during the warranty period, 

INTEC Controls | 

MSR-Electronic GmbH

 will repair or re-place the unit at its option. This warranty does not apply to 

units that have been modified, after repair attempts, or that have been damaged unintentionally 
or intentionally. The warranty also does not apply to units in which the sensing element has 
been poisoned. The above warranty is in lieu of all other express warranties, obligations or 
liabilities. 

A pre-authorized RMA number issued by INTEC Controls is required for returns.

This warranty applies only to PolyGard

®

2/PolyXeta

®

2 units. 

INTEC Controls | MSR-Electronic 

GmbH

 is not liable for consequential damages resulting from the purchase or use of 

PolyGard

®

2/PolyXeta

®

2 devices. 

1.5 Dispose of Device 

In accordance with Directive 2012/19/EU, the device must not be disposed of as
municipal waste. Return the device for disposal to your national sales organisa-
tion, which you can contact if you have any questions about disposal.

Outside the EU, you have to consider the corresponding directives. 

In accordance with Directive 2012/19/EU, the device must not be 

disposed of as municipal waste. Return the device for disposal to your 

national sales organization, which you can contact if you have any 

questions about disposal. 

Outside the EU, you have to consider the corresponding directives.  

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com

Specifications subject to change without notice. | GA_GC06_Modbus_supplement_E, 2022-04-05 | USA 221209 | Page 5 of 12

DGC6 Modbus Supplement – UserManual

Содержание Intec Controls PolyGard 2 DGC6

Страница 1: ...C 06 Modbus Modbus Supplement Version 2022 04 Release date 2022 04 05 Language English Name of file GA_GC06_Modbus_supple ment_E INTEC Controls 12700 Stowe Drive Suite 100 Poway CA 92064 Ph 858 578 78...

Страница 2: ...This page intentionally left blank...

Страница 3: ...ng bits of digital sensors 8 3 8 Display of the alarms and the respective latching bits of analog sensors 8 3 9 Relay status of the signal relays signal relay addr 1 96 Modbus register addr 7001 7096...

Страница 4: ...ng into account the current safety procedures for control instal lations The required equipotential bonding connections also e g secondary potential to ground or ground ing measures are to be carried...

Страница 5: ...ement has been poisoned The above warranty is in lieu of all other express warranties obligations or liabilities A pre authorized RMA number issued by INTEC Controls is required for returns This warra...

Страница 6: ...s inactive The resistor circuitry is already integrated in a Modbus master controller 3 Modbus Function 03 Reading of Registers Read Holding Registers reading of holding registers is used to receive d...

Страница 7: ...verage value of analog sensors sensor addr 1 32 Modbus register addr 4001 4032 Figure 4 Average value of analog sensors sensor addr 1 32 Modbus register addr 4001 4032 3 5 Measuring range of digital s...

Страница 8: ...g sensors Here the representation in the hexadecimal form is easier to read because the data are transmitted in the following form 0xFFFF 0x F F F F 0b 1111 1111 1111 1111 Local latching DGC 06 latchi...

Страница 9: ...fault message relay is in register 8000 The following values are possible 1 Relay is not active 0 Relay is active not energized 1 Relay is active energized 3 11 Error codes Modbus register addresses 9...

Страница 10: ...se these are dis played in the registers of the measured values c Register address 9097d 9104d Local error of the 8 Gas Controller Modules 1x GC06 7x EP06 Here 0x8100 MP error Error with any locally c...

Страница 11: ...its of the extension module address_2 Relay 9 is bit 0 to relay 12 is bit 3 Address 4 Relay information bits of the extension module address 3 Relay 13 is bit 0 to relay 16 is bit 3 Address 5 Relay in...

Страница 12: ...al registers in the DGC 06 Currently it is only possible to write on the own slave address Modbus address 0 see chapter 3 12 6 Modbus Function 15 Write Multiple Coils Write Multiple Coils writing mult...

Отзывы: