A-21
Adaptec SATAII RAID
Adding/Deleting Hotspares
To add, delete, or view hot spares:
1. From the ACU Main menu, select
Add/Delete Hotspares
.
2. Use the up and down arrow keys to highlight the disk you want to designate as
a Hotspare, then select
Insert
>
Enter
.
3. Press
Yes
when the following prompt is displayed:
Do you want to create spare? (Yes/No)
The Spare you have selected appears in the Selected Drive menu.
Configuring Disk Drives
v
Caution:
If the drive is already used in an array, configuring it may make the array
unusable.
Do not
configure a drive that is part of a boot array. To determine which drives
are associated with a particular array, see
Viewing Array Properties
.
You will not be able to configure drives already used in an array (even if it is
a broken array with missing members). You must delete the array before you
can configure the drives.
To configure drives:
1. From the ACU Main menu, select
Configure Drives
.
2. Use the up and down arrow keys to highlight the disk you wish to configure,
then press
Insert
.
3. Repeat Step 2 if you want to add another drive to be configured.
4. Press
Enter
.
5. Read the warning message and ensure that you have selected the correct
disk drives to configure. Type Y to continue.
Rebuilding Arrays
v
Note:
Rebuilding applies to Fault Tolerant arrays (RAID 1) only.
By replacing a failed drive of a RAID 1 array with a new drive, you can Rebuild to get
the array to Optimal status and assume fault tolerance. You can perform a Rebuild in
the following ways:
v
Note:
If no spare exists and a hard disk drive fails, you need to create a spare
before you can rebuild an array. See
Adding/ Deleting Hotspares
before
continuing your Rebuild.
System Shutdown Rebuild
You can shut down the system and replace the failed drive with a new one (of
equal or greater capacity). W hen the system is booted, you can assign the new
drive as a spare, and this will start the Rebuild task. All the data from the good
drive is copied to the new one, and the original RAID 1 array is recreated.