MSC CXC-BT
User Manual
55 / 84
Feature
Options
Description
COM B Setting:
Auto,
I/O 2F8h, IRQ 3
I/O 3F8h, IRQ 3,
4, 5, 6, 7 ,10,
11, 12
I/O 2F8h, IRQ 3,
4, 5, 6, 7 ,8,10,
11, 12
I/O 3E8h, IRQ 3,
4, 5, 6, 7 ,10,
11, 12
I/O 2E8h, IRQ 3,
4, 5, 6, 7 ,10,
11, 12
Resource setting for COM A on Winbond SIO
COM B Mode:
Normal, IrDA1-2
ASK-IR 1-4
Mode Setting for COM B on Winbond SIO
LPT:
Disabled,
Enabled
Enable or disable LPT on Winbond SIO
LPT Setting:
Auto,
I/O 378h, IRQ
5, 7
I/O 278, IRQ 5,
7
Resource setting for LPT A on Winbond SIO
LPT Mode:
SPP, EPP 1.9,
ECP, ECP +
EPP 1.9, Printer
Mode, EPP 1.7,
ECP+EPP 1.7
Mode setting for LPT on Winbond SIO
WB627 PS/2 Controller
Disabled,
Enabled
Enable or disable the WB627 PS/2 controller.
Note:
The above super IO menus will only appear if the SuperIO device is discovered on the
carrier board.
6.3.18 EC Hardware Monitoring
Feature
Options
Description
CPU Fan Control
Manual, Sensor based
Define how the fan should be controlled:
manually set to a fixed duty cycle, or
temperature based auto control.
Содержание Avnet COM Express CXC-BT
Страница 10: ...MSC CXC BT User Manual 10 84 2 2 Block diagram...