![MSA GASGARD 8 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/msa/gasgard-8/gasgard-8_instruction-manual_1846477023.webp)
2.
Use the <SCROLL UP> or <SCROLL DOWN> buttons to
configure each of the four alarm levels (A1 through A4).
•
The choice is confirmed by pressing the <ACK/VALID>
button or rejected by pressing the <ESC/TEST> button.
•
Once confirmed, the alarm level selected can be set ON
or OFF by using the <SCROLL UP> or <SCROLL
DOWN> buttons.
NOTE: Setting alarm level OFF disables alarm
and relay outputs.
•
The choice is confirmed by pressing the <ACK/VALID>
button or rejected by pressing the <ESC/TEST> button.
•
Once confirmed, the alarm level setpoint can be configured.
•
Use the <SCROLL UP> or <SCROLL DOWN> buttons to
set the alarm level.
•
The choice is confirmed by pressing the <ACK/VALID>
button or rejected by pressing the <ESC/TEST> button.
•
Once confirmed, the alarm level can be set for release on
upscale (UP) or downscale (dO).
NOTE: The downscale setting is normally reserved for
oxygen deficiency.
•
The choice is confirmed by pressing the <ACK/VALID>
button or rejected by pressing the <ESC/TEST> button.
•
Once confirmed, the alarm can be set as energized (En)
or de-energized (dE) by using the <SCROLL UP> or
<SCROLL DOWN> buttons.
•
An alarm in the Energized Mode (failsafe)
energizes the relay in a non-alarm state and
de-energizes the relay in an alarm state.
•
The opposite is true for an alarm in the
De-energized Mode.
•
The choice is confirmed by pressing the <ACK/VALID>
button or rejected by pressing the <ESC/TEST> button.
•
Once confirmed, the alarm can be set as Latching (LAt),
Half-Latching (HALF), or Non-latching (nLAT) by using the
<SCROLL UP> or <SCROLL DOWN> buttons.