Connection data sheets for sensors
9010/20 LCD
Sensor data sheet D-7100
Part No.: D0791610
Terminal Block
9010/9020
Sensor Type D-7100
Caution:
Before connecting the measuring head bridge current, check hardware
and software settings.
On the 9010/9020 LCD, the cable shield is applied on one side.
Sensor type:
Catalytic/passive/constant current supply [3 wire passive]
Connection data:
Bridge current:
270 mA/310 mA, for methane only
Maximum rated current:
350 mA
Maximum rated voltage:
2.8 V
Power requirement:
1.0 W [excluding cable lengths]
Connection cable:
3-lead, 80 % shielded
Maximum loop resistance:
32 Ohm
Maximum cable length:
1,000 m [with 1.5 mm
2
cross-section]
Cable diameter:
8...13 mm
Permitted cable cross-section: 0.75 – 2.5 mm
2
Cable gland thread:
M 20 x 1,5
Conditions for
use:
Assembly:
Wall-mounted
Ingress protection:
IP 54/EN 60529
Explosion protection:
Ex II 2G EEx d e IIC T5 /T6
Approval:
DMT 98 ATEX E016 X
Temperature:
-20 °C to + 40 °C [T6] /-20 °C to +55 °C [T5]
Humidity:
5–95% rel. humidity; non-condensing
Atmospheric Pressure:
950 – 1,100 hPa
Weight:
Approximately 1.24 kg
Dimensions W x D x H:
150 mm x 88 mm x 158 mm
Housing material:
Cast aluminium [polyester-coated]
Содержание 9010 LCD
Страница 1: ...Operating Manual CONTROL UNIT MODELS 9010 and 9020 LCD Order No 10093590 02 ...
Страница 2: ...MSA AUER GmbH Thiemannstrasse 1 D 12059 Berlin Germany MSA AUER GmbH All rights reserved ...
Страница 84: ...Control Unit Models 9010 LCD and 9020 LCD 84 Appendix MSA GB ...
Страница 86: ...N o part no DATA DATE DESCRIZIONE DESCRIPTION PREPARATO PREPARED BY APPROVATO APPROVED BY REVISIONE REVISION ...
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 90: ...No part no DATA DATE REVISIONI REVISIONS PREPARATO PREPARED BY APPROVATO APPROVED BY REVISIONE REVISION ...
Страница 94: ......
Страница 98: ......
Страница 99: ......