Maintenance and Cleaning

4.1

Maintenance Instructions

To maintain readiness for use, the device must be inspected regularly, checked for 
integrity, tightness and, if necessary, cleaned [do not use metal brushes!].  
As the device contains a chemical which is sensitive to moisture, it is packed in an 
airtight container and is sealed at the factory. 
The frequency of inspection depends on the device load [

Æ

chapter 4.4]. 

For used and/or opened devices, the chemical canister must always be replaced, 
reuse is not permitted. Internal checks and any repairs to the devies are to be car-
ried out by the MSA Customer Service or authorized service centers. 

4.2

Return of Used Device

For return of used or opened devices, observe the following:
-

Pack the device and components in the device containers only after they have 
cooled down and are dry.

-

No organic substances must enter the chemical canisters [e.g. solvents, oils, 
etc.].

-

Observe transport regulations [

Æ

chapter 5].

If the complete device cannot be packed in the container, the following procedure 
is required:
-

Remove the chemical canister from the device:

(1) Therefor loosen the clamp and remove the breathing bag and breathing tube.
(2) Pack the chemical canister inside the container and seal with the original lock-

ing assembly of the container.

Z

Do not use finely cutted filling material.

-

Place the other components of the device with the closed container in a carefully 
packed package.

-

The components must be complete and undamaged.

Содержание SSR 90

Страница 1: ...Operating Manual MSA AUER SSR 90 K60 EN 13794 K 60 S Order No 10112006 00...

Страница 2: ...MSA AUER GmbH Thiemannstrasse 1 D 12059 Berlin Germany MSA AUER GmbH All rights reserved...

Страница 3: ...2 Function 7 2 3 Marking 8 2 4 Demonstration and Training Device 8 3 Use 9 3 1 Important Escape Rules 9 3 2 Donning the Device 9 4 Maintenance and Cleaning 12 4 1 Maintenance Instructions 12 4 2 Retu...

Страница 4: ...lar the safety instructions as well as the information for the use and operation of the product must be carefully read and observed Furthermore the national regulations applicable in the user s countr...

Страница 5: ...ctions in this manual 1 3 Safety and Precautionary Measures Attention Chemical Oxygen Escape Devices used in mining may be subject to par ticular Mining Regulations that are to be observed There is an...

Страница 6: ...n enclosed and sealed sturdy stainless steel container A Inhalation 6 Neck strap B Exhalation 7 Waist belt 1 Nose clip 8 Quick starter 2 Gas protective goggles 9 KO2 canister 3 Breathing tube with mou...

Страница 7: ...ng circuit When in operation the exhaled air is transferred into the chemical canister with the potassium hyperoxide The potassi um hyperoxide reacts with the humidity and the carbon dioxide of the ex...

Страница 8: ...canister The inhalation air is tak en from the ambient air and the exhalation air is expelled outside The demonstration and training device is comparable in size weight external con struction handling...

Страница 9: ...the breathing bag otherwise lifesaving oxygen may be lost 5 The mouthpiece must be tight between teeth and lips and be tightly en closed with the lips The device must always be available for emergenc...

Страница 10: ...the container using the neck strap Otherwise the device could be damaged and thus would no longer pro vide secure protection Attention Activate the device before donning any equipment Inserting Mouthp...

Страница 11: ...by rubber nipples pull nose pads apart and fit them unto nose Fit Waist Belt 12 Fit waist belt on the right side and tighten Fit Goggles 13 Remove goggles from neck strap 14 Fit the goggles 15 Tighte...

Страница 12: ...or authorized service centers 4 2 Return of Used Device For return of used or opened devices observe the following Pack the device and components in the device containers only after they have cooled...

Страница 13: ...aps into the tightness tester in such a way that the cover points towards the door 2 Close the door and lock 3 Set timer to 90 s 4 Create overpressure with the lever i e push the lever downwards until...

Страница 14: ...for inspection Inspection Before and after carrying External visual check Check that the seal is intact and that there are no external damages on the device Annully Tightness check2 2 Tightness test...

Страница 15: ...6 Disposal The chemical canister contains strong alkaline and oxidizing substances potassium hydroxide potassium carbonate and potassium hyperoxide For disposal local regulations are to be observed 7...

Отзывы: