background image

MS 104/5

 

ML46758, Rev. 01

 

June 2002

 

LED Indicators 

The LEDs are described in Table 2, below. 

Table 2:  Front Panel LEDs 

LED 

Status 

Significance 

ON 

MS 104/5 receiving power. 

PWR

 

OFF MS 

104/5 

not 

receiving power. 

ON 

Port P 1 link 

OK

P1 L

 

OFF 

Port P 1 link 

absent 

or

 faulty

ON 

Port P 1 activity

4

 present

P1 A 

OFF 

Port P 1 activity 

absent

ON 

Port P 2 link 

OK

P2 L

 

OFF 

Port P 2 link 

absent 

or

 faulty

ON 

Port P 2 activity

 present

P2 A 

OFF 

Port P 2 activity 

absent

ON 

Port P 3 link 

OK

P3 L

 

OFF 

Port P 3 link 

absent 

or

 faulty

ON 

Port P 3 activity

 present

P3 A 

OFF 

Port P 3 activity 

absent

ON 

Port P 4 link 

OK

P4 L

 

OFF 

Port P 4 link 

absent 

or

 faulty

ON 

Port P 4 activity

 present

P4 A 

OFF 

Port P 4 activity 

absent

ON 

Port P 5 link 

OK

P5 L

 

OFF 

Port P 5 link 

absent 

or

 faulty

ON 

Port P 5 activity

 present

P5 A 

OFF 

Port P 5 activity 

absent

ON 

Ports P 1 PRI and P 1 SEC set to operate in mutual 
redundancy mode. 

RED

 

OFF 

Port P 1 PRI set to operate as a regular 100Base-FX 
port while port P 1 SEC is disabled. 

ON 

Port PRI OK and receiving. 

PRI 

OFF Port 

PRI 

not

 OK or not receiving. 

ON 

Port SEC OK and receiving. 

SEC 

OFF Port 

SEC 

not

 OK or not receiving. 

                                            

4

 transmission/reception 

 

11

 

 

Содержание MS 104

Страница 1: ...MS 104 5 Ethernet Switches User Manual MRV Communications Inc URL http www mrv com...

Страница 2: ...the use of the contents of this document since the customer bears sole responsibility Trademarks All trademarks are the property of their respective holders Copyright 2002 by MRV All rights reserved N...

Страница 3: ...ations 6 Features 6 Available 6 Optional 7 Layout 8 Front View 8 Ports 9 DIP Switch 9 LED Indicators 11 Installation and Setup 12 Package Contents 12 Procedure 12 Operation 12 Troubleshooting 13 Produ...

Страница 4: ...s of the MS 104 and MS 105 6 Figure 2 MS 104F2 8 Figure 3 MS 105F 8 Figure 4 MS 105FR 8 Figure 5 Interconnection of MS 104 5 and another Device 12 Tables Table 1 DIP Switch Setting 9 Table 2 Front Pan...

Страница 5: ...ess Control MDI Media Dependent Interface MM MultiMode SM SingleMode ToS Type of Service Safety Requirements Caution To reduce risk of electrical shock and fire and to maintain proper operation ensure...

Страница 6: ...whether it is a runt jabber or CRC error packet and discarding it if it is so Auto Negotation or Auto Sensing Automatic self reconfiguration capability of the 10BASE T 100BASE TX switching ports to o...

Страница 7: ...nly send and receive unicast packets to each other Optional Packet Prioritization Assignment of high or low processing priority to a packet on the basis of Port VLAN or ToS Flow Control Forcing of the...

Страница 8: ...002 As another example ports P1 and P3 can be put in one group ports P2 and P4 in another Layout Front View Following are the front views of the MS 104F2 MS 105F and MS 105FR Figure 2 MS 104F2 Figure...

Страница 9: ...s marked AUTO 10 100 and FD HD AUTO designates auto negotiation 10 100 designates 10 100 Mbps data rate FD HD designates full duplex half duplex Each toggle marked with a number e g 2 3 4 or 5 is func...

Страница 10: ...ive only if Auto negotiation DIP switch toggle 4 position is down i e if auto negotiation is disabled UP Set Port 2 to operate in Half Duplex mode Effective only if Auto negotiation DIP switch toggle...

Страница 11: ...FF Port P 3 link absent or faulty ON Port P 3 activity present P3 A OFF Port P 3 activity absent ON Port P 4 link OK P4 L OFF Port P 4 link absent or faulty ON Port P 4 activity present P4 A OFF Port...

Страница 12: ...nel Note If the device port to which the MS 104 5 electrical data port is connected does not have auto negotiation capability the MS 104 5 port operates in half duplex mode and at the same speed of th...

Страница 13: ...nd of fiberoptic cable 3 Check fiberoptic cable 4 Clean connectors as described in Appendix B Cleaning Optical Connectors 3 Copper port L LED off Bad STP UTP cable connection 1 Check electrical cable...

Страница 14: ...er Budget 9 dB to 24 dB model dependent see Appendix A Models Electrical Data Port Supported Speeds Connector Type Connector Pinout MDI X MDI 10 and 100 Mbps RJ45 8 pin shielded female 1 Tx 2 Tx 3 Rx...

Страница 15: ...s one redundant 100BaseFX port switch MM 1310nm 0 2km DSC MS105FR MT M 4 10 100BaseTX ports one redundant 100BaseFX port MM 1310nm 0 2km MT RJ MS105FR S1 4 10 100BaseTX ports one redundant 100BaseFX p...

Страница 16: ...mination Isopropyl alcohol Solvent for contaminants Tissues Soft multi layered fabric made from non recycled cellulose Procedure The procedure for cleaning connectors is as follows 1 If no stains are...

Отзывы: